beautypg.com

En g l is h english – Pfister GT34-4NSS User Manual

Page 6

background image

E

N

G

L

IS

H

ENGLISH

22

23

21

20

22 HANDLE REMOVAL
Turn off water before proceeding!

Carefully pry off handle button (22A) using

a small screwdriver or blade. Using a 3/32” Allen wrench, loosen set screw (22C)

and remove Lever Handle (22B). Reassemble handle by reversing steps.

23 CARTRIDGE REPLACEMENT
Turn off water supplies and relieve pressure before working on your faucet.
Remove handle – see above. Remove the Dome Cap (23A) by unscrewing
counter clockwise. Using pliers, unscrew the Retainer Ring (23B). Carefully
remove the Cartridge (23C) by pulling it straight up and out. Reassemble
faucet by reversing steps.

MAINTENANCE & CARE

21 FLUSHING & AERATOR CLEANING
After installation is complete, remove Aerator Housing (21A). Turn Valve
(21B) on and allow both hot and cold water to run for at least one minute each.
While water is running, check for leaks. To clean the aerator, disassemble Aerator
Housing (21A) by separating the Aerator Shell (21C), Basket (21D), and Washer
(21E). Once parts have been cleaned, reassemble by reversing steps.

20 SIDE SPRAY OPERATION
(For products with side spray). The Side Spray (20A) can be pulled forward
to spray water in any direction. To activate the Side Spray, press the Toggle
Button (20B) located on the back of the Side Spray (20A).