Page 19
PCXZinstall
Schlumberger Electronic Dispenser Option 98
Programming Example
Schlumberger dispensers may be configured to operate in many different modes. Below is a listing of
the option programming in the dispenser that is necessary for correct operation with the PCXZ. These
parameters may be obtained by entering into the configuration mode on the dispenser, then
executing an option dump using option 98. Refer to Schlumberger dispenser programmer’s guide for instructions.
Option #
Description
Setting
01
Access Code
0
11
Paymode Control — DISABLE OTHER PAYMODE
0
12
CNG Dispenser Mode
0
13
Side 1 Satellite — NO SATELLITE UNIT
1
13
Side 2 Satellite — NO SATELLITE UNIT
2
14
Master & Satellite Flow Enabled — NO CONCURRENT FLOW
0
15
Display Board Type — ICON DISPLAY EQUIPPED
1
16
Enable Icons — DISPLAY ICONS ENABLED
1
17
Flash Cash/Credit — FLASHING ICONS DISABLED
0
18
Single Hose — MULTI-HOSE OPERATION
0
23
Dispenser Handle Debounce Time
025
24
Enable Presets — NO PRESET KEYBOARD
0
24
Enable Presets — NO PRESET KEYBOARD
0
25
Comm Mode — XPIC COMM SUPPORT
4
26
Card Reader/Printer Hardware — LEFT-UP HW INSTALLED
2
28
Pulser Type
Single
29
Meter Type — GALLON METER INSTALLED
1
34
Max Flow Rate
0
36
Large Valve Prepay Slow Down Time — TIME IN SECONDS
0.200
37
Small Valve Prepay Slow Down Time — TIME IN SECONDS
0.000
38
Line Pressure Valve Delay
3.000
39
Flow Before Opening — LARGE VALVE
000
40
Amount of Flow Before Display Update — UNITS OF VOLUME
10
41
Num Prods-Side 1
3
41
Num Prods-Side 2
3
42
Num Pay Modes-Side 1
1
42
Num Pay Modes-Side 2
1
Side 2 Programming
Display Position
1
Dispenser Handle
1
Product
00
Base Product 1
00
Base Product 2
15
Meter/Valve Set 1
1
Meter/Valve Set 2
0
Sub-Dispenser 1
1
Sub-Dispenser 2
0