beautypg.com

Dimensions size 12, 30, Standard specifications, Series d double valves – Ross Controls 3_2 VALVES SERIES DM2 D User Manual

Page 7: Size 30 size 12

background image

SIZE 30

SIZE 12

View X

(Base mounting hole pattern)

Valve envelope

(Based in overall hole dimnsions at left.)

12.61

(320.23)

with Pressure

Switch

11.27
(286.26)

View X

(Base mounting hole pattern)

Valve envelope

(Based in overall hole dimnsions at left.)

14.25
(361.98)

15.48

(393.14)

with Pressure

Switch

DM

Series D Double Valves

DIMENSIONS – inches (mm)

STANDARD SPECIFICATIONS: For DM

Series D double valves.

Pilot Solenoids: According to VDE 0580. Enclosure rating

according to DIN 40050, IEC 60529 IP65. Two solenoids, rated
for continuous duty (

additional solenoid on optional reset).

Standard Voltages: 110 volts, 50/60 Hz; 220** volts, 50/60 Hz;

24 volts DC. For other voltages, consult ROSS.
** 220 volts AC not available in the U.S. (OSHA regulations limit

press control voltage to no more than 120 volts AC. Specify voltage

and frequency on order.
Power Consumption (each solenoid):
Size 2, 4, 12, 30:

For primary and reset solenoids:
6.0 watts on DC; 15.8 VA inrush and 10.4 VA holding on AC.
Size 8:

Primary solenoids:
15 watts on DC; 36 VA inrush and 24.6 VA holding on AC.
Reset solenoid:
6.0 watts on DC; 15.8 VA inrush and 10.4 VA holding on AC.
Electrical connection:
Size 2, 4, 8, 12, 30: DIN 43650, Form A. Order connectors separately.

Ambient Temperature: 15° to 120°F (-10° to 50°C).
Media Temperature: 40° to 175°F (4° to 80°C).
Flow Media: Filtered, lubricated or unlubricated (mineral oils

according to DIN 51519, viscosity classes 32-46); 5-micron

recommended.
Inlet Pressure:
Size 2:

45 to 150 psig (3.1 to 10.3 bar).

Size 4, 8, 12, 30:

30 to 120 psig (2.1 to 8.3 bar).

Reset Pressure: For remote air reset option – must be equal to

inlet pressure.
Manual Pressure: Encapsulated, push button actuation.
Pressure Switch (Status Indicator) Rating: Contacts - 5 amps

at 250 volts AC, or 5 amps at 30 volts DC.
Monitoring: Dynamically, cyclically, internally during each actuating

and de-actuating movement. Monitoring function has memory and

requires an overt act to reset unit after lockout.
Mounting orientation: Preferably horizontally (valve on top of base)

or vertically (with pilot solenoids on top).

IMPORTANT NOTE: Please read carefully and thoroughly all of the CAUTIONS on the inside back cover.

C

V

:

1 to 2: 8.86
2 to 3: 20.78

C

V

:

1 to 2: 20.22
2 to 3: 53.68

www.rosscontrols.com

7