Ordering information, Series d double valves – Ross Controls 3_2 VALVES SERIES DM2 D User Manual
Page 5
![background image](/manuals/358727/5/background.png)
DM
2®
Series D Double Valves
BASE MODEL NUMBERS and
BASE SPECIFIC INFORMATION
STATUS INDICATOR
1
......................................... YES
X
...........................................NO
RESET TYPE
1
..................................REMOTE
2
.............................. SOLENOID
4
.................................. MANUAL
VOLTAGE
A
............................. 24 volts DC
B
........... 110 volts AC, 50/60 Hz
C
** ........ 220 volts AC, 50/60 Hz
DM2D
D
A
4
2 A 1
1
HOW TO ORDER
(Choose your options (in red) to configure your valve model number.)
** 220 VAC not available in the U.S.
(OSHA regulations limit press control
voltage to no more than 120 volts AC).
PRODUCT
THREAD
BSPP .............................................
D
NPT ...............................................
N
N/A (no base) ................................
X
REVISION LEVEL
BASIC SIZE
2......................................................
2
4......................................................
4
8......................................................
5
12....................................................
6
30....................................................
8
BASE PORT SIZE
Size 2
1/4 inlet – 1/4 outlet ........................
0
3/8 inlet – 3/8 outlet ........................
1
Size 4
1/2 inlet – 1/2 outlet ........................
2
1/2 inlet – 3/4 outlet ........................
3
Size 8
3/4 inlet – 3/4 outlet ........................
4
1 inlet – 1 outlet ..............................
5
Size 12
1inlet – 1outlet ................................
6
1inlet – 11/2 outlet ............................
7
Size 30
11/2 inlet – 2 outlet ...........................
8
Valve only (less base) .................
X
Valve Port Size
Base
Status Weight
Size Inlet Outlet Model Number* Indicator lb (kg)
2
1/4 1/4
1872C91
No
1.7 (0.8)
2
1/4 1/4
1873C91
Yes
2.1 (1.0)
2
3/8 3/8
1874C91
No
1.7 (0.8)
2
3/8 3/8
1875C91
Yes
2.1 (1.0)
4
1/2 1/2
1697C91
No
1.7 (0.8)
4
1/2 1/2
1698C91
Yes
2.3 (1.1)
4
1/2 3/4
1699C91
No
1.7 (0.8)
4
1/2 3/4
1700C91
Yes
2.3 (1.1)
8
3/4 3/4
1701C91
No
3.6 (1.6)
8
3/4 3/4
1702C91
Yes
4.2 (1.9)
8
1 1
1703C91
No
3.6 (1.6)
8
1 1
1704C91
Yes
4.2 (1.9)
12
1 1
1705C91
No
6.2 (2.8)
12
1 1
1706C91
Yes
6.8 (3.1)
12
1 11/2
1707C91
No
6.2 (2.8)
12
1 11/2
1708C91
Yes
6.8 (3.1)
30
11/2 2
1709C91
No
12.0 (5.4)
30
11/2 2
1710C91
Yes
12.6 (5.7)
*NPT port threads. For BSPP threads add a “D“ prefix to the
model number, e.g., D1872C91.
Valve Weight: Valve and base assembly
with status indicator and solenoid reset.
Size 2: 5.0 lb (2.3 kg).
Size 4: 6.0 lb (2.8 kg).
Size 8: 9.1 lb (4.2 kg).
Size 12: 15.5 lb (7.1 kg).
Size 30: 32.6 lb (14.8 kg).
www.rosscontrols.com
5