Cautions, warranty, Cautions, Standard warranty – Ross Controls 3_2 VALVES SERIES DM2 D User Manual
Page 15

CAUTIONS
PRE-INSTALLATION or SERVICE
1. Before servicing a valve or other pneumatic component, be 
sure that all sources of energy are turned off, the entire pneumatic 
system is shut off and exhausted, and all power sources are locked 
out (ref: OSHA 1910.147, EN 1037).
2. All ROSS products, including service kits and parts, should 
be installed and/or serviced only by persons having training and 
experience with pneumatic equipment. Because any installation 
can be tampered with or need servicing after installation, persons 
responsible for the safety of others or the care of equipment must 
check every installation on a regular basis and perform all necessary 
maintenance.
3. All applicable instructions should be read and complied with 
before using any fluid power system in order to prevent harm to 
persons or equipment. In addition, overhauled or serviced valves 
must be functionally tested prior to installation and use.
4. Each ROSS product should be used within its specification limits. 
In addition, use only ROSS parts to repair ROSS products. Failure 
to follow these directions can adversely affect the performance of 
the product or result in the potential for human injury or damage 
to property.
FILTRATION and LUBRICATION
5. Dirt, scale, moisture, etc. are present in virtually every air system. 
Although some valves are more tolerant of these contaminants than 
others, best performance will be realized if a filter is installed to clean 
the air supply, thus preventing contaminants from interfering with 
the proper performance of the equipment. ROSS recommends a 
filter with a 5-micron rating for normal applications.
6. All standard ROSS filters and lubricators with polycarbonate 
plastic bowls are designed for compressed air applications only. 
Do not  fail to use the metal bowl guard, where provided, to 
minimize danger from high pressure fragmentation in the event of 
bowl failure. Do not expose these products to certain fluids, such 
as alcohol or liquefied petroleum gas, as they can cause bowls to 
rupture, creating a combustible condition, hazardous leakage, and 
the potential for human injury or damage to property. Immediately 
replace a crazed, cracked, or deteriorated bowl. When bowl gets 
dirty, replace it or wipe it with a clean dry cloth.
7. Only use lubricants which are compatible with materials used 
in the valves and other components in the system. Normally, 
compatible lubricants are petroleum based oils with oxidation 
inhibitors, an aniline point between 180°F (82°C) and 220°F (104°C), 
and an ISO 32, or lighter, viscosity. Avoid oils with phosphate type 
additives which can harm polyurethane components, potentially 
leading to valve failure which risks human injury, and/or damage 
to property.
AVOID INTAKE/EXHAUST RESTRICTION
8. Do not restrict the air flow in the supply line. To do so could reduce 
the pressure of the supply air below the minimum requirements for 
the valve and thereby cause erratic action.
9. Do not restrict a valve’s exhaust port as this can adversely affect 
its operation. Exhaust silencers must be resistant to clogging and 
must have flow capacities at least as great as the exhaust capacities 
of the valves. Contamination of the silencer can result in reduced 
flow and increased back pressure.
ROSS expressly disclaims all warranties and responsibility for any 
unsatisfactory performance or injuries caused by the use of the 
wrong type, wrong size, or an inadequately maintained silencer 
installed with a ROSS product.
POWER PRESSES
10. Mechanical power presses and other potentially hazardous 
machinery using a pneumatically controlled clutch and brake 
mechanism must use a press control double valve with a monitoring 
device. A double valve without a self-contained monitoring device 
should be used only in conjunction with a control system which 
assures monitoring of the valve. All double valve installations 
involving hazardous applications should incorporate a monitoring 
system which inhibits further operation of the valve and machine 
in the event of a failure within the valve mechanism.
ENERGY ISOLATION/EMERGENCY STOP
11. Per specifications and regulations, ROSS
L-O-X
®
valves and
L-O-X
®
valves with EEZ-ON
®
operation are defined as energy
isolation devices, NOT AS EMERGENCY STOP DEVICES.
All products sold by ROSS CONTROLS are warranted for a one-year period [with the exception of all Filters, Regulators and 
Lubricators (“FRLs”) which are warranted for a period of seven years] from the date of purchase to be free of defects in material 
and workmanship. ROSS’ obligation under this warranty is limited to repair or replacement of the product or refund of the purchase 
price paid solely at the discretion of ROSS and provided such product is returned to ROSS freight prepaid and upon examination 
by ROSS is found to be defective. This warranty becomes void in the event that product has been subject to misuse, misapplication, 
improper maintenance, modification or tampering. 
THE WARRANTY EXPRESSED ABOVE IS IN LIEU OF AND EXCLUSIVE OF ALL OTHER WARRANTIES AND ROSS EXPRESSLY 
DISCLAIMS ALL OTHER WARRANTIES EITHER EXPRESSED OR IMPLIED WITH RESPECT TO MERCHANTABILITY OR 
FITNESS FOR A PARTICULAR PURPOSE. ROSS MAKES NO WARRANTY WITH RESPECT TO ITS PRODUCTS MEETING 
THE PROVISIONS OF ANY GOVERNMENTAL OCCUPATIONAL SAFETY AND/OR HEALTH LAWS OR REGULATIONS. IN NO 
EVENT IS ROSS LIABLE TO PURCHASER, USER, THEIR EMPLOYEES OR OTHERS FOR INCIDENTAL OR CONSEQUENTIAL 
DAMAGES WHICH MAY RESULT FROM A BREACH OF THE WARRANTY DESCRIBED ABOVE OR THE USE OR MISUSE OF 
THE PRODUCTS. NO STATEMENT OF ANY REPRESENTATIVE OR EMPLOYEE OF ROSS MAY EXTEND THE LIABILITY OF 
ROSS AS SET FORTH HEREIN.
STANDARD WARRANTY
www.rosscontrols.com