Ups configuration – American Megatrends MAN-STOR-ITX27-CLI User Manual
Page 35

Chapter Two: Command Set
29
UPS Configuration
These commands configure the UPS for power management.
Command
Argument
Description
get UPS
-i/--info
-x/--xml
Displays the existing UPS
configuration.
get UPS
-i/--info
-m/--monitor
-x/--xml
Display the monitoring
configuration for the configured
UPS devices.
set UPS
-d/--disable
-x/--xml
Disables automatic shutdown.
set UPS
-e/--enable or
-d/--disable
-b/--battery
-t/--timeout
-m/--mode {1}
-x/--xml
For example: set –e –b 10 –t 3 –m 1 ups
Sets the UPS configuration to
given values. The enable mode is
to denote the shutdown option.
Timeout should be given in
minutes. Battery is the minimum
battery value below which the
shutdown is triggered Mode checks
whether it set to master or slave.
Note:
Minimum Battery value should be
between 0 and 100 %
Timeout value should be between
0 and 1000 minutes
set UPS
-e/--enable or
d/--disable
-b/--battery
-t/--timeout
-m/--mode {2}
-i/--masterip <{HostName/Master Ip>
-x/--xml
For example: set -e -b 35 -t 300 -m 2 -i 10.0.0.218
ups
Sets the UPS configuration to
given values. The battery value
indicates the minimum battery
value at which the alert has to be
generated. Timeout should be
given in minutes. Mode is set to
slave and the masterip is IP
Address of the master.
Note:
Minimum Battery value should be
between 0 and 100
Timeout value should be between
0 and 1000
config UPS
-i/--info
-x/--xml
Displays currently configured
driver for UPS monitoring.
config UPS
-l/--list
-x/--xml
Displays list of available drivers.
config UPS
-d/--driver
-p/--port
-x/--xml
For example: config –d 2 –p 1 ups
Sets driver to use with UPS
monitoring.
Driver number is from list obtained
from –list command.
Port value:
1 – COM1
2 – COM2
u - USB