American Megatrends MAN-STOR-ITX27-CLI User Manual
Page 29

Chapter Two: Command Set
23
Command
Argument
Description
-l / --ldname 
-m/--cachemode 
Cache Modes - ld 
 0 - None 1 - Read 
 2 - Write 3 - Read-Write 
rescan raid
-n/--controllerno 
 
Initiates rescanning of the storage 
bus connected to the controller. 
remove raid
-t/--type {spare} 
-d / --diskname 
-l/ --ldname 
-n/--controllerno 
For example: remove -t spare -d 3 -n 0 raid 
 remove -t spare -l /dev/md0 -d /dev/sdb raid 
Removes a drive assigned as a 
spare disk or dedicated disk. 
add raid
-t/--type {spare} 
-d / --diskname or slotindex or 
enclosurenumber:slotindex- 
l/--ldname 
-n/--controllerno 
For example: add -t spare -d 1:4 -n 0 raid 
Adds the given drive as a global or 
dedicated hot spare. 
upgrade raid
-t/--type {controller} 
-n/--controllerno 
-o /--code  
-l/ --length 
Upgrades the firmware for 
controller. 
upgrade raid
-t/--type {pd} 
-d / --diskname 
-n/--controllerno 
-o /--code  
-l/ --length 
Upgrades the firmware for a 
physical disk. 
