beautypg.com

Hydraulic systems – Ramsey Winch HD-234 User Manual

Page 8

background image

HYDRAULIC SYSTEMS

Refer to performance charts, below, to properly match your hydraulic system to
the HD-234 winch performance. The charts consist of:

1. Line pull (lbs.) first layer vs. working pressure (PSI). STATIC (solid line) refers

to hoisting a suspended load from rest; DYNAMIC (dashed line) refers to
maintaining the motion of a moving load.

2. Line speed, first layer (FPM) vs. gallons per minute (GPM).

Performance based on a motor displacement of 3.6 cubic inches with 15
GPM maximum flow rate.

HD-234 PERFORMANCE
8,000 LB. DUTY RATING - 34:1 GEAR RATIO

WORKING PRESSURE, PSI

FIRS

T LAYER

LIN

E

P

U

LL, LBS

3,000

2,000

1,000

0

5,000

4,000

7,000

6,000

8,000

DY

NAM

IC

2000

1000

STATIC

3000

FLOW, GPM

L

INE SP

EED

, FPM

FIRS

T LAYER

0

0

5

5

10

15

20

10

15

25

30

35

8