beautypg.com

Paasche Airbrush D-PL User Manual

Paasche, Air compressor

background image

D

Air Compressor

1/4 H.P., 115 V., 60 Cyl.

INSTRUCTIONS AND PARTS LIST D-8/2005

Supersedes Instructions & Parts List D-5/2002

Model D Diaphragm Compressor was designed with the
artist in mind, offering quiet dependable service with
sufficient pressure to operate any artist airbrush. Delivers
up to 1/2 C.F.M. at 20 p.s.i. (Maximum 40 p.s.i.) and weighs
20 Ibs. (Shipping Weight 22 lbs.)

INSTRUCTIONS:
BEFORE OPERATING COMPRESSOR, READ AND
FOLLOW DIRECTIONS AS OUTLINED BELOW.

1. The D Compressor is equipped with a 3 wire cord with

On/Off Switch and a 1/4 H.P.,115 V.A.C., 1 Phase, 60
cycle motor. NOTE: Before plugging in, check to make
sure available power is the same as that noted on motor
name plate. Turn off switch and remove plug from wall
outlet when leaving unit unattended.

2. Connect air hose to air outlet on unit.
3. Plug unit into properly wired electrical receptacle.
4. Hold hose and point loose end away from you. Turn on

switch and allow a few moments to blow hose clean of
any foreign particles.

5. Turn switch off.
6. Connect airbrush to hose using V-62 Wrench.

Printed in the U.S.A.

Paasche Airbrush Company

4311 North Normandy
Chicago, IL 60634-1395
Phone: 773-867-9191 • Fax: 773-867-9198

Website: paascheairbrush.com
E-Mail: [email protected]

CAUTION: When a flammable liquid is sprayed, there may be
danger of fire or explosion especially in a closed room: keep
compressor at least 20 feet away from areas where hazardous
concentrations of flammable vapors are likely to occur.
Compressor may not start when pressure is in the airline. Bleed
air by pressing Air Valve Button on Airbrush. Do Not Start and
Stop Compressor in Rapid Succession–May Burn Out Motor.
ATTENTION: Lorsqu’un liquide inflammable est pulverise, il
peut y avoir danger d’incendie ou d’explosion, specialement
dans une piece fermee; garder le compresseur a au moins 20
pieds des endroits ou des concentrations dangereuses de
vapeurs inflammables sont susceptibles de se produire.

NOTE: Set compressor on floor while operating, to remove
danger of unit falling from an elevated surface, possibly
causing damage to unit or injury. To reduce any noticeable
vibration or movement; suggest placing compressor on a
carpeted surface etc.

Troubleshooting:
1. Motor will not run if:

a. It is not plugged in.
b. The switch is defective or in the off position.
c. There is a blown fuse in house circuit.
d. There is residual pressure in air line:

1. Press finger button on airbrush to release pressure

2. Motor runs but has no air pressure if:

a. The D-77 Screws are loose or missing.
b. D-55, D-54, D-66 are dirty or broken.
c. The D-352 Rod is broken.
d. The D-56 Diaphragm is worn or cracked.

3. Noisy operation occurs when:

a. The D-79 Screw is loose.
b. The D-83 Screw is loose.
c. Connecting Rod Bearing is worn.
d. Puller or Pusher Washer is broken.
e. Inlet Filter is not in place.

NOTE: When reassembling compressor parts, make sure
they are positioned exactly as they were before
disassembly.
SERVICE:
1. Clean intake filter weekly. Replace filter if clogged with

paint overspray.

D Compressor has sufficient air capacity for the

following Paasche Airbrushes, using light fluids:

• Capacity for 2: F#1, V#1, V#2, VJR#1 or VJR#2 Airbrushes.
• Capacity for 2: H#1, H#3, VL#1 or VL#3 Airbrushes.
• Capacity for 1: AB, ABL, H#5, or VL#5 Airbrush.
• Capacity for 1: AUFB-0, AURB-0, or AURB-1 Spray Gun.
• Capacity for 1: 62-1-3 or 62-2-3 (3 oz.) Sprayers.

paasche