Paasche Airbrush D220R-PL User Manual
D220r air compressor
INSTRUCTION AND PARTS LIST D220R, 8/31/2011
INSTRUCTION AND PARTS LIST D220R, 8/25/11
WARNING: When a flammable liquid is sprayed, there may
be danger of fire or explosion especially in a closed room:
keep compressor at least 20 feet away from areas where
hazardous concentrations of flammable vapors are likely to
occur. Disconnect power before servicing.
ATTENTION: Lorsqu'un liquide inflammable est pulverise, il
peut y avoir danger d'incendie ou d'explosion, specialement
dans une piece fermee; garder le compresseur a au moins
20 pieds des endroits ou des concentrations dangereuses de
vapeurs inflammables sont susceptibles de se produire.
Debrancher avant toute maintenance.
Paasche Airbrush Company
4311 North Normandy Avenue
Chicago, IL 60634-1395
Phone: 773-867-9191 • Fax: 773-867-9198
Website: paascheairbrush.com
E-Mail: [email protected]
D220R Air Compressor
1/6 HP, 110V, 60Hz, 3 AMP, 180 Watts, .7 CFM @ 20 PSI,
maximum working pressure 40 PSI.
Shipping Weight: 4.5 kgs (10 lbs.)
OPERATION: OILLESS - NEEDS NO LUBRICATION
The compressor is maintenance free. To avoid mal-functions and
premature wear and tear, the following points should be observed.
1. WARNING: Plug the power cord into a 110V.-60Hz Cycle grounded
outlet. Do not use an adapter to by-pass the grounding feature. Do not
operate compressor in a wet area.
2. Place compressor on a level surface, preferably on the floor.
3. Carrying compressor while operating is not advisable.
4. Do not let the compressor run unnecessarily, i.e. the unit should be
switched off when the airbrush is not being used.
5. Always remove the power cord from the electric outlet when making
adjustment or changing parts.
6. Always provide plenty of ventilation while spraying.
7. Never smoke or eat while spraying.
8. Wear a respirator and eye protection when spraying.
TROUBLE-SHOOTING:
1. Low air flow
Possible causes:
What to do:
-Diaphragm damaged
-Change the diaphragm
-Screws are too loose
-Tighten the screws
-Air hose leaking
-Check seal, or change
2. Noisy operation
Possible causes:
What to do:
-Screws are too tight
- Loosen the screws, and
then tighten them equally.
Do not over tighten.
-Bearing fault
-Return to Factory.
3. Humming but does not work
Possible causes:
What to do:
-Screws are too tight
-Loosen the screws, and
then tighten them equally.
Do not over tighten.
-Armature fault
-Return to the Factory.
4. Does not work
Possible causes:
What to do:
-Armature fault
-Return to the Factory.
INSTRUCTIONS:
BEFORE OPERATING COMPRESSOR, READ AND FOLLOW
DIRECTIONS AS OUTLINED BELOW.
1. Set Compressor on floor. Compressor vibrates and may “walk” off
elevated surfaces, possibly causing damage to unit or injury to you.
2. Plug cord into 115 Volt, 60 Cy., grounded outlet.
GROUNDING INSTRUCTIONS:
This product should be grounded. In the event of an electrical short circuit,
grounding reduces the risk of electrical shock by providing an escape wire
for the electric current. This product is equipped with a cord having a
grounding wire with an appropriate grounding plug. The plug must be
plugged into an outlet that is properly installed and grounded in accordance
with all local codes and ordinances.
DANGER—Improper use of the grounding plug can result in a risk of
electrical shock.If repair or replacement of the cord or plug is necessary,
D220R AIR COMPRESSOR PARTS
D220-16
Diaphragm
Optional Items:
HFM-2-1/4
Air Manifold
D220R Air Compressor, 110V., 60Hz.,
with R-75 Air Filter Regulator
Manufactured in China for Paasche
do not connect the grounding wire to either flat blade terminal. The wire
with insulation having an outer surface that is green with or without yellow
stripes is the grounding wire.
Check with a qualified electrician or serviceman if the grounding
instructions are not completely understood, or if in doubt as to whether the
product is properly grounded. DO NOT modify the plug provided; if it will
not fit the outlet, have the proper outlet installed by a qualified electrician.
This product is for use on nominal 120-volt circuit and has a grounding plug
that looks like the plug illustrated in sketch below. Make sure that the product
is connected to an outlet having the same configuration as the plug. No
adapter should be used with this product.
EXTENSION CORDS:
Use only a 3-wire extension cord that has a 3-blade grounding plug, and
a 3-slot receptacle that will accept the plug on the product. Make sure
your extension cord is in good condition. When using an extension cord,
be sure to use one heavy enough to carry the current the product will
draw. An undersized cord will cause a drop in line voltage resulting in loss
of power and overheating.
AUTOMATIC THERMAL LIMITED
The D220 will shut off automatically when overheated. to restart, release
air pressure and let D220 cool down. Automatic reset.
Grounding Method
Grounded Outlet
Grounding Pin
Cover of Grounded
Outlet Box