A-1
INSTALLATION
POWER WAVE
®
S700
A-1
TECHNICAL SPECIFICATIONS - POWER WAVE
®
S700
RECOMMENDED INPUT WIRE AND FUSE SIZES
1
INPUT
VOLTAGE / 3 PHASE/
FREQUENCY
380/3/50
460/3/60
500/3/60
575/3/60
TIME DELAY FUSE
OR BREAKER
2
AMPERAGE
90
80
70
60
Type 75C
Copper Wire in
Conduit AWG
(IEC) Sizes 40C
(104°F) Ambient
6 (16)
6 (16)
8 (10)
8 (10)
Maximum
Input Amperes
75
62
57
50
RATED OUTPUT
POWER SOURCE-INPUT VOLTAGE AND CURRENT
Model
K3279-1
Duty Cycle
100% rating
Process
GMAW
GMAW-P
GTAW
SMAW
FCAW-GS
FCAW-SS
Input Amperes
55/46/42/38
Idle Power
(Watts)
205W Fan Off
(Max.)
360W Fan On
(Max.)
Power Factor @
Rated Output
.95
Input Voltage ± 10%
380-415/440-460/500/575
1. Based on U.S. National electrical Code
2. Also called " inverse time" or "thermal / magnetic" circuit breakers; circuit breakers that have a delay in trip-
ping action that decreases as the magnitude of the current increases.
Duty Cycle
60%
100%
60%
100%
60%
100%
60%
100%
60%
100%
60%
100%
Amperes
900A
700A
900A
700A
900A
700A
900A
700A
900A
700A
900A
700A
Volts at Rated
Amperes
44V
34V
44V
OCV
(U0)
70V AVG.
78V PEAK
70V AVG.
78V PEAK
24V AVG.
27V PEAK
60V AVG.
67V PEAK
70V AVG.
78V PEAK
70V AVG.
78V PEAK