A-3
INSTALLATION
POWER WAVE
®
S700
A-3
SAFETY PRECAUTIONS Read
this
entire installation section before you start installa-
tion.
ELECTRIC SHOCK can kill.
• Only qualified personnel should
perform this installation.
• Turn the input power OFF at the
disconnect switch or fuse box before working on
this equipment. Turn off the input power to any
other equipment connected to the welding system
at the disconnect switch or fuse box before work-
ing on the equipment.
• Do not touch electrically hot parts.
• Always connect the Power Wave
®
S700 ground-
ing lug (located inside the reconnect input
access door) to a proper safety (Earth) ground.
-------------------------------------------------------------
SUITABLE LOCATION
Location and ventilation for cooling
Place the welder where clean cooling air can freely
circulate in through the rear louvers and out through
the case sides and front. Dirt, dust, or any foreign
material that can be drawn into the welder should be
kept at a minimum. The use of air filters on the air
intake is not recommended because normal air flow
may be restricted. Failure to observe these precau-
tions can result in excessive operating temperatures
and nuisance shutdowns.
• Place the welder where clean cooling air can freely
circulate in through the rear louvers and out
through the case sides and front.
• Dirt, dust, or any foreign material that can be drawn
into the welder should be kept at a minimum. The
use of air filters on the air intake is not recommend-
ed because normal air flow may be restricted.
Failure to observe these precautions can result in
excessive operating temperatures and nuisance
shutdowns.
• The best practice is to keep the machine in a dry,
sheltered area.
WARNING
Environmental limitations
The Power Wave
®
S700 is IP23 rated for use in an
outdoor environment. The Power Wave
®
S700 should
not be subjected to falling water during use nor
should any parts of it be submerged in water. Doing
so may cause improper operation as well as pose a
safety hazard. The best practice is to keep the
machine in a dry, sheltered area.
• Do not mount the Power Wave
®
S700 over com-
bustible surfaces. Where there is a combustible
surface directly under stationary or fixed electrical
equipment, that surface shall be covered with a
steel plate at least .060” (1.6mm) thick, which shall
extend not less than 5.90” (150mm) beyond the
equipment on all sides.
LIFTING
Lift the machine by the lift bail only. The lift bail is
designed to lift the power source only. Do not
attempt to lift the Power Wave
®
S700 with acces-
sories attached to it.
STACKING
The Power Wave
®
S700 cannot be stacked.
INPUT AND GROUND CONNECTIONS
Only a qualified electrician should connect the Power
Wave
®
S700. Installation should be made in accor-
dance with the appropriate National Electrical Code,
all local codes and the information in this manual.
MACHINE GROUNDING
The frame of the welder must be grounded. A ground
terminal marked with the symbol shown is located
inside the reconnect/input access door for this pur-
pose.
See your local and national electrical codes for prop-
er grounding methods.
• Lift only with equipment of ade-
quate lifting capacity.
• Be sure machine is stable when
lifting.
• Do not operate machine while
suspended when lifting.
FALLING
EQUIPMENT can
cause injury.
-------------------------------------------------------------
WARNING