A-15

INSTALLATION

POWER WAVE

®

S700

A-15

Amperes

200

200

250

250

250

250

300

300

350

400

400

500

600

600

600

650

650

700

800

800

900

900

Percent Duty

Cycle

60

100

30

40

60

100

60

100

40

60

100

60

60

80

100

60

80

100

80

100

80

100

0 to 50 Ft.

2

2

3

2

1

1

1

2/0

1/0

2/0

3/0

2/0

3/0

2-1/0

2-1/0

3/0

2-1/0

2-2/0

3-1/0

2-3/0

2-4/0

3-3/0

50 to 100 Ft.

2

2

3

2

1

1

1

2/0

1/0

2/0

3/0

2/0

3/0

2-1/0

2-1/0

3/0

2-1/0

2-2/0

3-1/0

2-3/0

2-4/0

3-3/0

100 to 150 Ft.

2

2

2

1

1

1

1

2/0

2/0

2/0

3/0

3/0

3/0

2-1/0

2-1/0

4/0

2-1/0

2-3/0

3-1/0

2-3/0

2-4/0

3-3/0

150 to 200 Ft.

1

1

1

1

1

1

1/0

2/0

2/0

3/0

3/0

3/0

4/0

2-2/0

2-2/0

2-2/0

2-2/0

2-3/0

2-3/0

2-3/0

2-4/0

3-3/0

200 to 250 Ft.

1/0

1/0

1/0

1/0

1/0

1/0

2/0

3/0

3/0

4/0

4/0

4/0

2-3/0

2-3/0

2-3/0

2-3/0

2-3/0

2-4/0

2-4/0

2-4/0

4-2/0

3-3/0

CABLE SIZES FOR COMBINED LENGTHS OF ELECTRODE AND WORK
CABLES [RUBBER COVERED COPPER - RATED

167°F (75°C)]

**

OUTPUT CABLE GUIDELINES

(Table A.1)

** Tabled values are for operation at ambient temperatures of 104°F (40°C) and below. Applications above 104°F (40°C) may

require cables larger than recommended, or cables rated higher than 167°F (75°C).