beautypg.com

Lincoln Electric IM10163 FLEX FEED 74 HT User Manual

Page 37

background image

A-30

INSTALLATION

FLEX FEED™ 74 HT

RELAY CONNECTIONS

The Flex Feed

74 HT includes a DPDT relay for

switching power for accessories. The relay closes
whenever the gas solenoid turns on.

The ratings of the relay are:

Normally Open

30 amps @ 277 VAC 20 amp @ 28 VDC

Normally Closed

2 amps @ 480 VAC 3 amps @ 28 VDC

To make connections to the relay:

1. Turn power OFF at the welding power supply.
2. Remove the (4) screws securing the roof with a

5/16” nut driver.

3. Remove the (4) screw securing the User Interface

with a 5/16” nut driver.

4. Remove the plastic plug button at the rear of the

feeder and replace with an appropriate electrical
bushing. Route the wires through the bushing to the
relay.

5. Reassemble.

FIGURE A.44

NORMALLY CLOSED

CONTACTS

NORMALLY OPENED

CONTACTS

24

3

7

8

6