beautypg.com

Installation, Technical specifications, Circulator – Lincoln Electric IM10109 CIRCULATOR User Manual

Page 9

background image

A-2

INSTALLATION

CIRCULATOR

A-2

TECHNICAL SPECIFICATIONS:

Model#: AD1326-8

CIRCULATOR

MAKE/MODEL

DESCRIPTION

INPUT VOLTAGE NOMINAL CURRENT

+/- 10% (MAX.)

CIRCULATOR

AIR HANDLING 380-480V/3~/50-60Hz 13.9A

INPUT

HEIGHT WIDTH

DEPTH

WEIGHT

213.6 in.

92.1 in.

53.2 in.

1764 lbs.

5425 mm

2340 mm

1350 mm

800 kg.

PHYSICAL DIMENSIONS

41

0

F (5

0

C) to 113

0

F (45

0

C) MAX.

80%

TEMPERATURE RANGE

RELATIVE HUMIDITY

Cellulose fibers provided with precoat

2 x 807 ft

2

(2 x 75 m

2

)

FILTER MATERIAL

FILTER SURFACE AREA

According to DIN EN 60335-2-69

FILTER CLASS L

Dry and Oil Free (ISO 8573-3 class 6)

85 PSI (6 Bar) MAX

COMPRESSED AIR QUALITY

REQUIRED PRESSURE

Quick Connect Coupling ø 9mm (CEJN 320)

Max: 5.3 ft

3

/min. (87 lbs./in

2

)

Depending on the degree of filter saturation

COMPRESSED AIR CONNECTION

COMPRESSED AIR CONSUMPTION

90 Minutes MAX

OFFLINE CLEANING CYCLE DURATION

F with PTC

IP54

INSULATION CLASS FAN

PROTECTION CLASS