Connecting Outlet Unit

1. Place the duct extension on top of the silencer.

Carefully maneuver into position so the previously
installed duct connector fits inside the extension
duct and secure using eight self tapping screws.
Screws not included. See Figure A.9.

2. Place the outlet unit on top of the duct extension

and secure using eight self tapping screws.
Screws not included. See Figure A.10.

The duct extension MUST be fastened to the filter unit
to strengthen the configuration. If necessary, the duct
extension may also be fastened to a wall. To fasten
the duct extension to the filter unit, proceed as follows:

3. Using the previously mounted angle iron located

on the top of the air inlet module, fasten the duct
extension to the to the air inlet module via the sup-
port brackets and threaded rods. Make sure the
duct extension and the filter base are parallel to
each other.

See Figure A.4.

Connection Of Silencer

1. Place a duct connector into the exhaust hole on

the top of the fan cabinet. Secure into place using
eight self tapping screws. Screws not included.
See Figure A.8.

NOTE: The duct connector will slide half way into the

top of the fan cabinet.

2. Carefully place the silencer on top of the fan cabi-

net. Carefully maneuver into position so the previ-
ously installed duct connector fits inside the
silencer. See Figure A.8.

NOTE: There is no specific orientation of top and bot-

tom on the silencer.

3. Place the second duct connector into the exhaust

hole on the top of the silencer. Secure into place
using eight self tapping screws. Screws not includ-
ed. See Figure A.8.

FIGURE A.8

DUCT CONNECTOR

SILENCER

DUCT CONNECTOR

FAN CABINET

EXHAUST HOLE

FIGURE A.9

DUCT EXTENSION

SILENCER

FIGURE A.10

OUTLET UNIT

DUCT EXTENSION

CAUTION