beautypg.com

Maintenance, Replacing the filters, Warning – Lincoln Electric IM10109 CIRCULATOR User Manual

Page 26

background image

D-3

MAINTENANCE

D-3

CIRCULATOR

REPLACING THE FILTERS

When To Replace the Filters

• When damaged.

• When the extraction capacity is significantly reduced.

• In cases of a continuous alarm situation while the

cleaning mechanism is running.

NOTE: You must learn from experience when to

replace the filters. The life span of the filters
strongly depends on the composition of the
welding fumes, humidity, etc.

How To Replace Filters

1. Disconnect input power and the compressed air

connection.

2. Remove the associated components necessary to

gain access to the filter.

See Installation for

removal in reverse order. See Figure D.1.

3. Using a 13mm wrench, remove the nuts and asso-

ciated washers securing the filter lid.

See Figure

A.2.

4. Remove the upper filter. The filter has been fitted

with special plastic handles for this purpose.

See

Figure A.2.

5. Remove the filter ring.

6. Remove the lower filter.

7. Position the new filters, filter ring and filter lid in

reverse order and mount the lid housing. Note the
correct position of the filter ring, filter lid and
the condition of the seal on the cover.

8. Check the condition of the lid on the lid housing.

9. Reset hour counter if applicable.

NOTE: For all other technical issues, please contact

The Lincoln Electric Automation Division
Environmental Solutions Hotline at 1-888-935-
3878 option 4.

• Saturated filters and/or full drums often

contain dust and dirt particles which
can be inhaled and cause harm.

• When replacing filters always wear a

high-quality and approved respirator.

• Wrap everything in a properly closed plastic bag

and dispose of in compliance with the local regula-
tions.

• Always replace both filters at the same time.

----------------------------------------------------------------------

WARNING

S23385-14
“RING”

S23385-5

(SET OF 2)

S23281-62

“VALVE”

S23585-13
“CLOSING DRUM VALVE”

S23385-12
“FLANGE DRUM 100”

S23281-61
“PISTON”

S23281-67
“COMPLETE CLEANING
SYSTEM”

S23281-68
“O-RING”

FIGURE D.1 – CIRCULATOR FILTERS & COMPONENTS