A-7

INSTALLATION

CIRCULATOR

A-7

Particulate Collection Drum

1. Mount the flexible duct connector onto the drum

flange and tighten the adjustable clamps using a
slot head screwdriver. See Figure A.11.

NOTE: Make sure the flexible duct covers and the

black rubber gasket are located on the drum
flange.

2. Remove shrink wrap and cardboard from the bot-

tom of the hopper.

3. Position the particulate collection drum directly

below the hopper.

4. Connect the other end of the flexible duct connec-

tor to the bottom of the hopper. See Figure A.11.

5. Fully extend the three turnbuckle distance holders

to meet the top of the collection drum. See Figure
A.11.

6. Make sure the damper is open. The damper con-

trol lever is located on the front of the particulate
collection drum and should be in the vertical posi-
tion when in operation.

Compressed Air Connection

1. Connect compressed air line to pressure reducing

valve. Compressed air supply must be a minimum
of 90 PSI. See Figure A.12.

Mounting the Control Panel

1. Install mounting hardware to back of control panel.

Note proper position of mounting bolts and nylon
washers. See Figure A.13.

2. Mount the control panel to the side of the fan cabi-

net.

3. If mounting to the top case rail, use ½” self tapping

screws

4. If mounting to the sheet metal, pre-drill holes and

use ½” mounting bolts with appropriate washers
and lock washers.

FIGURE A.12

PRESSURE

REDUCING

VALVE

FIGURE A.13

560 mm (22

.05 in.)

± 150 m

m

(5.9 in.)

CONTROL PANEL

MOUNTING BOLTS

NYLON WASHERS

S

F1

F2

F3

F4

ES

C

OK

LOG

O!

TD

FIGURE A.11

FLEXIBLE DUCT CONNECTOR

DRUM FLANGE

HOPPER

ADJUSTABLE CLAMPS

COLLECTION DRUM