beautypg.com

Maintenance – Lincoln Electric IM10109 CIRCULATOR User Manual

Page 25

background image

D-2

MAINTENANCE

D-2

MAINTENANCE SCHEDULE

NOTE: * REQUIRES Lincoln Electric factory autho-

rized service technician.

AS NEEDED

• Replace filters (See filter replacement instructions).

• Inspect and test functionality of the filter media

cleaning system. *

• Program and verify system auto on/off timer (PLC). *

• Clean spiral ducting. *

MONTHLY

• Check particulate collection barrels and dispose of

particulate if necessary.

• Check and log filter pressure.

EVERY 6 MONTHS

• Ensure that the Cubic Feet per Minute (CFM) is

operating to the engineered specifications based on
the individual system *

STATIFLEX 6000 Filter Housings

• Check the integrity of the filter housing and tighten

all bolts and screws as needed.

• Clean housing with a non-aggressive detergent.

• Check the connections to the duct work, seal if nec-

essary.

• Check incoming air pressure.

• Inspect and clean (with a non-aggressive detergent)

the filter control box.

YEARLY

• Change membrane S23281-62. *

• Change O-Ring S23281-68. *

MOTOR/FAN HOUSING
(SOUND ABSORBING ENCLOSURE)

• Check the integrity of the fan housing (sound

absorbing box) and tighten all bolts and screws if
necessary.

• Verify unit is level and adjust if necessary.

• Clean housing (sound absorbing enclosure) with a

non-aggressive detergent.

• Check connection of silencer to fan housing and seal

if necessary.

• Check connection of ductwork to silencer and seal if

necessary.

• Check fan motor blades for encrusted particles and

clean if necessary.

• Inspect and clean control panel with a non-aggres-

sive detergent.

• Inspect flex connection (blue) inside fan housing

(sound absorbing enclosure).

• Check inlets and outlets for tears or wear.

CONTROL PANEL

• Check for functionality of control panel fan.

• Inspect and clean any buildup or dirt on fan blade

impellers in control panel.

• Inspect and replace control panel filters if necessary.

CIRCULATOR