Table 6-1: icmc information panel description – IEI Integration AFL2-W15B-H61 User Manual
Page 136

Page 118
AFL2-W15B-H61
Fan
The system fan speed. “0” indicates the fan is off.
System Info
CPU Frequency
The CPU frequency parameters.
CPU Loading
The CPU loading parameters.
CPU Type
The brand name of the CPU being used in the system.
Light Fanless Settings
BIOS Overwrite
Use this option to determine either to follow the BIOS setting or the iCMC
setting for the light fanless operation. This setting is configured through
BIOS (see Section 4.3.9). The options include:
- Enable: The light fanless operation will take effect based on the
“Temperature of Fanless” set in the BIOS.
- Disable: The light fanless operation will take effect based on the
“Temperature of Fanless” set in the iCMC.
Temperature of Fanless When the environment temperature 1 is lower than the temperature set
here, the fan will turn off. When the environment temperature 1 is higher
than the temperature set here, the fan will turn on. A list of available options
is shown below:
Disabled
4°C
8°C
12°C
16°C
20°C
24°C
28°C
32°C (Default)
36°C
40°C
For safety reason, the fan will turn on automatically to cool down the system
when the CPU temperature exceeds 80 ºC, no matter the Temperature of
Fanless is enabled or not.
Chart Visible
On/Off On: show the chart panel
Off: hide the chart panel
Table 6-1: iCMC Information Panel Description