Mode Setting [Full On Mode]

Use the Mode Setting option to configure the second fan.

Î

Full On Mode

D

EFAULT

Fan is on all the time

Î

Automatic mode

The fan adjusts its speed using these settings:

Temp. Limit of OFF

Temp. Limit of Start

Fan Start PWM

Slope PWM 1

Î

PWM Manual mode

The fan spins at the speed set in:

Fan

PWM

control

ƒ

Temp. Limit of OFF [000]

WARNING:

CPU failure can result if this value is set too high

The fan will turn off if the temperature falls below this value.

ƒ

Minimum Value: 0°C

ƒ

Maximum Value: 127°C

ƒ

Temp. Limit of Start [020]

WARNING:

CPU failure can result if this value is set too high

When the fan is off, it will only start when the temperature exceeds this setting.

ƒ

Minimum Value: 0°C

ƒ

Maximum Value: 127°C