Page 69
Î Change Settings [Auto]
Use the Change Settings option to change the serial port IO port address and interrupt
address.
Î
Auto D
EFAULT
The serial port IO port address and interrupt address
are automatically detected.
Î
IO=2F8h;
IRQ=3
Serial Port I/O port address is 2F8h and the interrupt
address is IRQ3
Î
IO=3F8h;
IRQ=3, 4,
5, 6, 7, 10,
11, 12
Serial Port I/O port address is 3F8h and the interrupt
address is IRQ3, 4, 5, 6, 7, 10, 11, 12
Î
IO=2F8h;
IRQ=3, 4,
5, 6, 7, 10,
11, 12
Serial Port I/O port address is 2F8h and the interrupt
address is IRQ3, 4, 5, 6, 7, 10, 11, 12
Î
IO=3E8h;
IRQ=3, 4,
5, 6, 7, 10,
11, 12
Serial Port I/O port address is 3E8h and the interrupt
address is IRQ3, 4, 5, 6, 7, 10, 11, 12
Î
IO=2E8h;
IRQ=3, 4,
5, 6, 7, 10,
11, 12
Serial Port I/O port address is 2E8h and the interrupt
address is IRQ3, 4, 5, 6, 7, 10, 11, 12
Î Serial Port1 Mode [Standard Serial Port Mode]
Use the Serial Port1 Mode option to select the transmitting and receiving mode for the
first serial port.
Î
Standard Serial Port Mode
D
EFAULT
Serial Port 1 mode is standard
Î
IrDA 1.0
Serial Port 1 mode is IrDA 1.0 (HP SIR)
Î
ASKIR Mode
Serial Port 1 mode is ASK IR