beautypg.com

IEI Integration PCISA-9652 v1.01 User Manual

Page 141

background image

PCISA -9652 Half-Size CPU Card

Page 121

Disabled D

EFAULT

Remote access is disabled.

Enabled

Remote access configuration options shown below

appear:

Serial Port Number

Serial Port Mode

Redirection after BIOS POST

Terminal Type

These configuration options are discussed below.

Serial Port Number [COM1]

Use the Serial Port Number option allows users to select the serial port used for remote

access.

COM1 D

EFAULT

System is remotely accessed through COM1

COM2

System is remotely accessed through COM2

NOTE: Make sure the selected COM port is enabled through the Super I/O configuration

menu.

Base Address, IRQ [3F8h,4]

The Base Address, IRQ option cannot be configured and only shows the interrupt

address of the serial port listed above.

Serial Port Mode [115200 8,n,1]

Use the Serial Port Mode option to select baud rate through which the console redirection

is made. The following configuration options are available

115200 8,n,1 D

EFAULT

57600 8,n,1