beautypg.com

Installation, Special functions – Warner Electric MCS-836_836-1_836-2 User Manual

Page 3

background image

3

Warner Electric • 800-825-9050

P-241-78

Delay Drop: Immediate pull-ln (energize) of the out-
put device and a time delay for drop-out (de-
energize).

Dual Delay: Independently set time delays for both
puIl-in (energize) and drop-out (de-energize) of the
output module.

One-Shot: Provides a one-shot output. The output
device is energized by a transition of the input state,
and holds for a preset time independent of the photo-
electric input.

One-Shot Drop: Reverse action of the one-shot
function, the output device is energized and drops out
on the input transition of the photoelectric control.

Delayed One-Shot: Time delay prior to a one-shot
output. Delay on one-shot timing is independently
adjustable.
Delayed One-Shot Drop: Delay prior to a one-shot

drop similar to the one-shot drop but with a time
delay. Both delay and one-shot are independently
adjustable.

Installation

1. Select the desired timing functions.
2. Set appropriate switches to "ON" from table

below.

3. Place Light-Dark Selector Switch in the desired

position.

4. Insert timer module on pins in photoelectric

control, (NOTE: Power must be off.)

5. Adjust potentiometers for desired timing range.

Function

Normal Operation

Delay Pull
Delay Drop
Dual Delay
One-Shot
Delayed One-Shot
One-Shot Drop
Delayed One-Shot
Drop

Dark Operate Mode

Switches “On”

Unplug Timer

Use Jumper

7420-702-001

5

3,5

None

1, 2, 5, 6
1, 2, 4, 6

1, 2, 3, 5, 6
1, 2, 3, 4, 6

Pin

Selec-

tion

L/D

D

D

L*

D
D
D
D
D

Potentiometer(s)

Adjust

___

P-1
P-1
P-1 pull, P-2 drop
P-1
P-1 delay, P-2 O.S.
P-1
P-1 delay, P-2 O.S.

Light Operate Mode

Switches “On”

Unplug Timer

Use Jumper

7420-702-001

5

3,5

None

1, 2, 5, 6
1, 2, 4, 6

1, 2, 3, 5, 6
1, 2, 3, 4, 6

Pin

Selec-

tion

L/D

L

L

D*

L
L
L
L
L

Potentiometer(s)

Adjust

____

P-1
P-1
P-1 pull, P-2 drop
P-1
P-1 delay, P-2 O.S.
P-1
P-1 delay, P-2 O.S.

*NOTE: For proper operation of delay drop,
note that the light-dark switch must be reversed
for proper operation in the light & dark modes.

Special Functions

Motion Detection

2,4

D P-2

2, 3, 4

L P-2

Retriggerable or
integrating one-shot