Technical specifications
Size
200
400
800
1600
3200
6400
12800
N max. (VAR00)
tr/min
2600
2000
1700
1500
1500
-
-
N max. (VAR02)
tr/min
-
3000
2500
2200
1800
1500
1500
Travel P
mm 0.5
±0.1
0.5
±0.1
0.6
±0.1
0.8
±0.1
0.8
±0.1
1
±0.1
1
±0.1
Max. travel
mm
1
1.2
1.4
1.7
1.8
2.2
2.8
Coupling
55
65
75
90
100
125
180
Dimension E VAR05
mm 30
+2.20/0
35
+2.6/0
40
+3/0
45
+3.6/0
50
+3.6/0
60
+4.6/0
85
+6.4/0
Flange-screws (528) (VAR05) M8 x 20
M8 x 20
M10 x 25
M12 x 25
M16 x 25
M16 x 40
M20 x 40
Tightening torque
Nm
22
±2
22
±2
44
±4
76
±8
189
±18
189
±18
370
±37
Weight (VAR00, 02)
kg
20
25,5
35,2
61
122
220
380
Weight (VAR05)
kg
27,4
31,5
50,5
85,5
158
298
597
WARNER ELECTRIC EUROPE - Rue Champfleur, B.P. 20095, F - 49182 St Barthélemy d’Anjou Cedex
SM310gb - rev 11/04
2/6
We: WARNER ELECTRIC EUROPE, 7, rue Champfleur, B.P. 20095, F-49182 St Barthélemy d’Anjou Cedex
declare that the clutches made in our factories from St Barthélemy d’Anjou,
and hereafter designated : E210 and E220
are exclusively designed for incorporation into a machine and to be assembled with other equipments to create a machine. The operation of the
product is submitted to the conformity of the complete equipment, following the provisions of the machinery directive 98/37/EC and if electric to
the EMC directive 89/336 /EEC.
The conformity of the electric units to the Low Voltage directive 72/23 (modified) is supported by the full respect of the following standards :
NFC 79300 and VDE 05808/8.65.
Drawn up in St Barthélemy d’Anjou, july 2002
E. PRAT, General Managing Director
CONTENTS
1
Technical specifications
2
2
Precautions and restrictions on use
2
2.1
Restrictions on use
2
2.2
Precautions 2
and safety measures
3
Installation
3
3.1
Transport - storage
3
3.2
Handling
3
3.3
Installing
3
3.3.1 Installing VAR00 and VAR02
3
3.3.2 Installing VAR05
4
4
Maintenance
4
4.1
Maintenance
4
4.2
Spare parts
4
5
Electrical connection
5
5.1
Important recommendations
5
5.2
Power supply
5
6
Appendix
6
1
Technical specifications
NB : data for catalogue equipment
2
Precautions and restrictions on use
2.1
Restrictions on use
This equipment is designed for dry running. Any
oily material alters performance.
Exceeding the maximum speed of rotation stated
in the catalogue invalidates the warranty.
This equipment is designed for a maximum ambient
temperature of 40° (155°C casing class).
E210 and E220 clutches are designed to operate
with centreline horizontal. Vertical fitting is possible
only for VAR00.
2.2
Precautions in use and safety measures
During maintenance, ensure that the machine’s
moving parts are stationary and that there is no
risk of accidental start-up. All intervention have to be made
by qualified personnel, owning this manual.
Any modification made to the brake without the
express authorisation of a representative of Warner
Electric, in the same way than any use out of the contrac-
tual specifications accepted by "Warner Electric", will result
in the warranty being invalidated and Warner Electric will
no longer be liable in any way with regard to conformity.
Table 1
NB : data for catalogue equipment
2
Precautions and restrictions on use
2.1
Restrictions on use
This equipment is designed for dry running.
Any oily material alters performance.
Exceeding the maximum speed of rotation
stated in the catalogue invalidates the warranty.
This equipment is designed for a maximum
ambient temperature of 40° (155°C casing
class).
E210 and E220 clutches are designed to
operate with centreline horizontal. Vertical
fitting is possible only for VAR00.
2.2
Precautions in use and safety measures
During maintenance, ensure that the machine’s
moving parts are stationary and that there is no
risk
of accidental start-up. All intervention
have to be made by qualified personnel,
owning this manual.
Any modification made to the brake without
the express authorization of a representative of
Warner Electric, in the same way than any use
out of the contrac tual specifications accepted
by “Warner Electric”, will result in the warranty
being invalidated and Warner Electric will
no longer be liable in any way with regard to
conformity.
We:
WARNER ELECTRIC EUROPE, 7, rue Champfluer, B.P. 20095, F-49182 St Barthélemy d’Anjou Cedex declare that the clutches made in our
factories from St Barthélemy d’Anjou,
and hereafter designated:
E210 and E220
are exclusively designed for incorporation into a machine and to be assembled with other equipments to create a machine. The operation of the
product is submitted to the conformity of the complete equipment, following the provisions of the machinery directive 98/37/EC and if electric to the
EMC directive 89/336/EEC.
The conformity of the electric units to the Low Voltage directive 72/23 (modified) is supported by the full respect of the following standards: NFC
79300 and VDE 05808/8.65.
Drawn up in St Barthélemy d’Anjou, july 2002