Mode Selection

For single channel (alternate) operation, make sure
jumper is on the single side of the connection block.

NOTe: The control is shipped with the jumper
placed in the single mode operating position.

For simultaneous mode (dual) operation, remove
the jumper from the pins and reinstall on the dual
side of the connector block.

Control Mounting

1. Select the appropriate location to where the

control will be mounted. Insure sufficient air
space is maintained around and above the
control selected.

2. Using the dimensions of Figure 3 or Figure

4 depending on whether the CBC-400-XX or
CBC-450-XX is to be used, layout the dimensions
on the location selected or use the cut-out
template of Figure 5 or 6. (See page 53.)

NOTe: Insure that sufficient space is available
to accommodate wiring runs.

3. If using the cut-out template Figure 5 or 6, tape

template to location where control is to be
mounted. Using a center punch, mark the four
(4) mounting holes.

NOTe: Insure sufficient force is used so punch
marks are visible in panel when the template is
removed.

4. Drill the mounting holes using a #21 drill.

5. Tap the mounting holes using a 10-32 tap. Make

sure holes are free of burns and rough edges.

6. Using 10-32 screws with lockwashers, secure

the control to the panel or chassis securely.

NOTe: Make sure screws are tightened with
sufficient torque since control may be subjected
to light to moderate vibration on most machine
applications.

7. After mounting control, make sure area around

control and wiring run location are clean and
free of chips, shavings, etc. before proceeding
to wiring section.

8. Double check to insure sufficient space around

and above control. Insure cover or door assembly
does not contact control board when closed.