Alternate/Simultaneous Operation –

Three Wire Mode, Sinking Type Input

Devices

1. Refer to Figures 13a through 16a for various

switching devices which can be used.

2. Jumper the positive (+) inputs of the opto-

coupler Terminal Block TB-1, Terminal 1, 3,
and 5 together. Tighten terminals 1 and 3
securely.

3. Connect a DC power source, positive

voltage to Terminal 5.

a. Positive (+) DC if external power supply

is used. Tighten Terminal 5 securely.

b. Jumper from Terminal Block TB-1

Terminal 7 if internal DC supply is used.

Tighten both Terminals 5 and 7 securely.

4. Connect output side of the switching circuit

(start) to the channel 2 input negative side
(-) of the opto-coupler at Terminal Block
TB-1, Terminal 2.

a. Momentary switch contact

(normally open)

b. Normally open contact of form “C” Relay

c. Open collector output of NPN Transistor

for solid-state sensors

d. Collector of NPN output module for PLC

interface or computer card

Tighten Terminal 2 of Terminal Block TB-1
securely.

NOTe: With the exception of the relay
contact in 4b above, all other outputs or
switches must be momentary in nature.

5. Connect the input side of the switching

circuits if momentary switches or relay
contact is used to the negative side (-) of
the power source.

a. External negative (-) if external DC power

source is used.

b. Negative (-) or DC common of the internal

voltage source, Terminal 8 of TB-1.

6. Connect the output side of the switching circuit

(stop) to the Channel 1 input negative side (-) of
the opto-coupler at Terminal Block TB-1,
Terminal 4.

a. Momentary switch contact (normally open)

b. Normally closed relay contact of form “c”

relay

c. Open collector output of NPN Transistor for

solid-state sensors

d. Collector of NPN Output Module for PLC

interface or computer card

Tighten Terminal 4 of Terminal Block TB-1
securely.

NOTe: With the exception of the relay contact in
6b above, all other outputs or switches must be
momentary in nature.

7. Connect the input side of the switching circuits

of momentary switch or relay contact if used to
the negative side (-) of the power source.

a. External negative (-) if external DC power

source is used.

or,

b. Negative (-) or DC common of the internal

voltage source, Terminal 8 of TB-1.

8. For external sensors or when using PLC output

modules or computer cards, connect power to
sensors or cards accordingly.

a. External power source, positive (+) and

negative (-) to sensor power leads

or,

b. Internal power source, positive (+) Terminal 7,

TB-1 and negative (-) Terminal 8, TB-1 to
sensor power leads. Tighten Terminals 7 & 8
securely.

14