background image

Alternate/Simultaneous Operation – Two

Wire Mode, Sourcing Type Input

Devices

1. Refer to Figures 25a through 28a for various

switching devices which can be used.

2. Jumper the negative (-) inputs of the opto-

coupler, Terminal Block TB-1, Terminals 2,
4, and 6 together. Tighten Terminals 2 and 4
of Terminal Block TB-1 securely. Snug
Terminal 6 only at this time.

3. Connect a DC power source, negative (-) or

DC Common Terminal 6 of Terminal Block
TB-1.

a. Negative (-) or DC Common of external

DC power source to Terminal 6. Tighten
Terminal 6 securely.

or,

b. Jumper from Terminal 8 of Terminal

Block TB-1 DC Common (-) to Terminal 6
of Terminal Block TB-1 if internal DC
power source is used. Tighten both
Terminals 6 and 8 securely on Terminal
Block TB-1.

4. Connect a DC power source positive (+)

voltage to Terminal 1 of Terminal Block
TB-1.

a. Positive (+) DC of external DC power

source is used. Tighten Terminal 1, TB-1
securely.

or,

b. Jumper from Terminal 1 of Terminal

Block TB-1 to Terminal 7 (+) DC of TB-1
if internal DC power supply is used.
Tighten Terminal 1 only at this time.

5. Connect the output side of the switching

circuit to the Channel 1 input, positive side
(+) of the opto-coupler at Terminal Block
TB-1, Terminal 3.

a. Normally closed contact of mechanical

switch

b. Normally closed contact of relay contact

c. Open collector output of PNP Transistor

(normally on) for solid-state sensors

d. Collector output of PNP Transistor (normally

on) for PLC output module or computer card

Tighten Terminal 3 of Terminal Block TB-1
securely.

NOTe: For operation of the CBC-400/CBC-450
to power up with Channel 1 output “on” in
alternate mode or both outputs “off” in
simultaneous mode, the Channel 1 input
switch must be maintained closed for
mechanical switches or “on” in the case of
solid-state switches.

6. Connect the input side of the switching circuit

when mechanical switches are used to the
positive side (+) of the DC power source.

a. External positive (+) of the DC power source if

used

or,

b. Positive (+) of the internal DC power source at

Terminal 1 of Terminal Block TB-1 securely.

Tighten Terminal 7 of TB-1 securely.

7. For external sensors or when using PLC output

modules or computer cards, connect power
source to sensors or cards accordingly.

a. External power source, positive (+) and

negative (-) to appropriate leads on terminals

or,

b. Internal power source, positive (+) DC voltage

Terminal 7 of Terminal Block TB-1 and
negative (-) or DC Common Terminal 8 of
Terminal Block TB-1 to appropriate sensor
leads or terminals. Insure both Terminals 7
and 8 are snug at this time.

8. Optional Channel 2 Override Input Wiring

P-239-23 • 819-0500 Warner Electric • 800-825-9050

41

This manual is related to the following products: