beautypg.com

Figure 17a – Warner Electric CBC-450 User Manual

Page 24

background image

3. Open collector output of NPN

Transistor in PLC output module or
computer card.

Tighten Terminal 6 of Terminal Block
TB-1 securely at this time.

b. Connect the input side of the Channel 2

override switch to negative side (-) of the
DC power source.

1. External negative (-) of external DC

power source if used.

or,

2. Negative (-) or DC common of the

internal voltage source at Terminal 8
of Terminal Block TB-1. Tighten
Terminal 8 securely at this time.

9. Double check all input wiring and switching

circuit connection to insure proper wiring and
hook-up. Refer to figures 17a through 20a.

10. Make sure all Terminal Block connections on

Terminal Block TB-1 are securely tightened at
this time.

11. Double check any external sensor power wiring

and connections. Refer to the appropriate
sensor data sheets for connections.

12. This completes the input switching circuit

wiring. Make sure all debris, insulation chips
or wire fragments are cleaned up and control
circuit boards blown off with dry air before
proceeding.

13. Proceed to the start-up section of the manual

for start up and check out.

1

2

3

4

5

6

7

8

Channel 2

Input

+12 VDC

CLOSED- CH 1 OUT

OPEN- CH 2 OUT

START

OVERRIDE

DC COM

+

-

Channel 1

Input

+

-

Channel 2

Override

+

-

TB-1

Figure 17a

24

Warner Electric • 800-825-9050 P-239-23 • 819-0500

This manual is related to the following products: