beautypg.com

Vanguard RFD-200 S2 User Manual

Page 8

background image

RFD-200 S2 USER’S MANUAL

REV 2

5

Table 2. RFD-200 S2 Output Specifications

AC CURRENT OUTPUT

Range

No-Load Voltage

Load Voltage

Load Current

Load/Unload Times

10A

90 Vac

75 Vac

10 A

2 min / 15 min

40 A

25 Vac

20 Vac

40 A

1 min / 15 min

100 A

10 Vac

7.25 Vac

100 A

1 min / 15 min

100 A

10 Vac

3 Vac

250 A

1 sec / 5 min

AC VOLTAGE OUTPUT

Range

No-Load Voltage

Load Voltage

Load Current

Load/Unload Times

250 Vac

260 Vac

240 Vac

3 A

10 min / 45 min

DC VOLTAGE OUTPUT

Range

No-Load Voltage

Load Voltage

Load Current

Load/Unload Times

300 Vdc

300 Vdc

250 Vdc

2A

10 min / 45 min

Table 3. RFD-200 S2 Timing Accuracy

RFD-200 S2 TIMER SECOND DISPLAY

IN SECONDS AND CYCLES (50/60 HZ PROGRAMMABLE)

Range

Resolution

Accuracy

0 to 9.999 sec

1 ms

± (1 ms + 0.01%)

10.00 to 99.99 sec

10 ms

± (10 ms + 0.01%)

100.00 to 999.999 sec

100 ms

± (100 ms + 0.01%)

TIMER CYCLES DISPLAY

Range

Resolution

Accuracy

0 to 9.999 cycles

0.1 cycle

± (0.1 cycle + 0.01%)

1,000 to 49,999 cycles / 50 Hz

1 cycle

± (1 cycle + 0.01%)