beautypg.com

Vanguard RFD-200 S2 User Manual

Page 7

background image

REV 2 RFD-200 S2 USER’S MANUAL

4

1.3

RFD-200 S2 Technical Specifications

Table 1. RFD-200 S2 Technical Specifications

TYPE

Portable relay test set

INPUT POWER

100 – 120 Vac or 200 – 240 Vac (factory pre-set), 50/60 Hz

PHYSICAL SPECIFICATIONS

Dimensions: 16.8”W x 12.6”H x 12”D (42.7 cm x 32.0 cm x 30.5 cm);
Weight: 35 lbs (15.9 kg)

AMPERE METER INPUT

RANGES

Internal input range: 0 – 250 A; Accuracy: 2% of reading ± 10 mA,
External AC input range: 0 – 6A; Accuracy: 1% of reading ± 10mA
External DC input range: 0 – 6A; Accuracy: 0.5% of reading ±1 count
Measurement Method: True RMS for AC

VOLT METER INPUT RANGE

0 – 600.0V; AC accuracy: 1% of reading ±1 count; DC accuracy 0.5% of
reading ±1 count
Measurement Method: True RMS for AC

AUXILIARY POWER SUPPLIES

24 Vdc @ 1 A, 124 Vdc @ 0.25 A, 240 Vac @ 0.125 A

SAFETY

Designed to meet IEC61010 (1995), UL61010A-1, CSA-C22.2 standards

ENVIRONMENT

Operating: -10˚C to 50˚ C (15˚F to +122˚ F); Storage: -30˚ C to 70˚ C (-
22˚F to +158˚ F)

OPTIONS

Transportation case

WARRANTY

One year on parts and labor

NOTE

The above specifications are valid at nominal operating voltage and at a
temperature of 25

°C (77°F). Specifications may change without prior notice.