beautypg.com

Vanguard RFD-200 S2 User Manual

Page 10

background image

RFD-200 S2 USER’S MANUAL

REV 2

7

Table 4. Functional Descriptions of RFD-200 S2 Controls and Indicators

Item

Number

Panel Markings

Functional Description

1

COM

Current source common terminal

2

100A

100A current source terminal

3

40A

40A current source terminal

4

10A

10A current source terminal

5

0-250 Vac

3A

AC voltage source terminals

6

0-300 Vdc

3A

DC voltage source terminals

7

EXT INPUT

CURRENT

6A MAX

External current input terminals

8

Power

resistor

array

9

Back-lit LCD screen (20 characters by 4 lines), viewable in bright sunlight and
low-light levels

10

110-120 Vac

12A, 50-60 Hz

Power switch with built-in circuit breaker

11

GROUND

Ground terminal

12

VOLTAGE INPUT

600V MAX

External voltage input terminals

13

RS-232

RS-232C (serial) port for factory firmware programming and diagnostics

14

OUTPUT

CONTROL

Voltage and current source control knob

15

RFD-200 S2 timer, current source and voltage source control buttons

16

6A

External current input circuit breaker

17

CONTRAST

LCD screen contrast control button

18

240 VAC

.125A

240 Vac power supply fuse (1/8 A)

19

124 VDC

.25A

124 Vdc power supply fuse (1/4 A)

20

24 VDC

1A

24 Vdc power supply fuse (1A)

21

PWS SELECT

Auxiliary power supply selection button

22

240-260 VAC

240 Vac power supply output terminals

23

124-136 VDC

124 Vdc power supply output terminals

24

24-28 VDC

24 Vdc power supply output terminals

25

ON/OFF

Power supply ON/OFF button

26

Timer STOP method selection button

27

TIMER STOP

Timer STOP input terminals

28

Timer START method selection button

29

TIMER START

Timer START input terminals

30

METER SELECT

Internal/external current display selection button