Vanguard CT-8000 User Manual
Page 103

REV 2 CT-8000 USER’S MANUAL
98
4.2
Performing a Transducer Self-Test
You can check the transducer electronics by connecting the transducer to the CT-8000 and
running a transducer self-test using the instructions below:
a. Start from the “START-UP” menu:
Press the
[4]
key (DIAGNOSTICS).
b. The following screen will be displayed:
Press the
[3]
key (TEST TRANSDUCER).
c. The following screen will be displayed:
Move the transducer slider to a known distance and observe the display.
d. The screen will be updated with the new transducer position information:
If the transducer was moved 5 inches, the screen should display 5.00 IN. You can
continue to move the transducer slider and observe the screen values to make sure they
are correct. Press the
[STOP]
key to end the test and return to the “START-UP” menu.
TRANSDUCER TEST:
1= 5.00 IN / 360.0
x
2= 0.00 IN / 000.0
x
2= 0.00 IN / 000.0
x
TRANSDUCER TEST:
1= 0.00 IN / 000.0
x
2= 0.00 IN / 000.0
x
2= 0.00 IN / 000.0
x
1. SLOW CLOSE TEST
2. CHECK HOOKUP
3. TEST TRANSDUCER
4. NEXT PAGE
1. RUN TEST 03/10/10
2. GET RSLT 09:04:05
3. SETUP
4. DIAGNOSTICS