Vanguard VCBA S2 (DigiTMR S2, DigiTMR S2 PC, CT-6500 S2, CT-7000 S2, CT-7500 S2, CT-8000) User Manual
Page 21
REV 3 VCBA S2 VERSION 4.xx SOFTWARE MANUAL
18
Table 1. Description of Test Record Sections
Item
Number
Functional Description
1
Graph page number. Select which page to view from this drop-down menu.
2
Test record header information. Test record header information can include identifying information such
as the date and time the test was performed, the company name, model number, etc.
3
Contact channel timing information.
4
This section displays on-line timing information (if performed)
5
Stroke, velocity, over-travel, and bounce-back values for contact channel 1
6
Stroke, velocity, over-travel, and bounce-back values for contact channel 2
7
Stroke, velocity, over-travel, and bounce-back values for contact channel 3
8
Speed analysis information
9
Additional test parameters such as initiator current, trigger type, shot length, etc.
10
Travel Transducer Curve Color Legend
11
Current cursor location
12
Time, Current, Voltage, Stroke, Velocity, and Resistance values from current cursor location
13
Graph for contact channels 1-3
14
Travel curves for contacts 1-3
15
Coil initiate current graph
16
Voltage graph
Each section of the tabulated data can be collapsed or expanded. If a section is expanded, a “-”
sign will be displayed to the left of it. Clicking on the “-” sign will collapse the section and hide
its data. If a section is collapsed, a “+” sign will be displayed to the left of it. Clicking on the “+”
sign will expand the section and display its data.