beautypg.com

Ct-6500 operating instructions – Vanguard CT-6500 User Manual

Page 26

background image

CT-6500 Operating Instructions

19

9.1.1 Timing an OPEN Operation With No Insertion Resistors

Table 4.0 Open Operation With No Insertion Resistors

STEP

OPERATION

ACTION

DISPLAY

1

READY TIMER FOR BREAKER OPERATION.

PRESS #1 KEY.

INSERTION RESISTOR?

1.NO

2.YES

2

SELECT NO INSERTION RESISTOR.

PRESS #1 KEY.

TIMING WINDOWS:

1.WINDOW = 1 SEC

2.WINDOW = 10 SEC

3. WINDOW = 20 SEC

3

SELECT 1-SECOND TIMING WINDOW.

PRESS #1 KEY.

TRIGGER MODE:

1. Internal Trigger

2. External Trigger

4

SELECT INTERNAL TRIGGER.

PRESS #1 KEY.

TIMING MODE:

1. OPEN

2. CLOSE

3. O-C

4. C-0

5. O-C-O

5

SELECT OPEN OPERATION.

PRESS #1 KEY.

OPEN TIMING

Hold "ARM" Switch,

Then "START".

"STOP" to ABORT

6

INITIATE OPEN COMMAND.

HOLD THE "ARM"

SWITCH AND

PRESS THE "START"

KEY.

TEST IN PROGRESS

Hold "ARM" Until

Test complete.

(Up to 15 seconds)

7

OBSERVE BREAKER OPERATED.

ANALYZER IS READY TO OUTPUT RESULTS.

NONE.

1.TIME BREAKER

2.GET RESULT

3.SET-UP

4.DIAGNOSTIC

NOTE

One-second timing windows are used for breaker timing. The 10 and 20 second
timing windows are used for circuit-switcher timing.