beautypg.com

Figure 17. cominit and comwake timing measurements – Teledyne LeCroy QPHY-SATA User Manual

Page 38

background image

38

915745 Rev

G

Figure 17. COMINIT and COMWAKE Timing Measurements

OOB-06

– COMWAKE Gap Detection

This test measures the response of the product to COMWAKE with different gap widths. A signal generator is
used to send COMWAKE to the product. A device should respond to COMWAKE by sending COMWAKE followed
by ALIGN primitives. A host should respond to COMWAKE by sending ALIGN primitives. The setup is the same as
OOB-01.

When using the PeRT

3

the result is tested by the PeRT

3

and not by the oscilloscope.

When not using the PeRT

3

,the trigger output of the signal generator is used to indicate when a COMWAKE has

been sent. When the product responds to COMWAKE it should look similar to the following: