BRIEF HS LEVEL TEST DESCRIPTIONS

Name

Purpose

VOD-DATA-1

To verify that the Differential Voltages (VOD(0) and VOD(1)) of the DUT Data & Clock Lanes

HS transmitter are within the conformance limits.

VOD-DATA-0

VOD-CLK-1

VOD-CLK-0

VOHHS-Dp

To verify that the Single-Ended Output High Voltages (VOHHS(DP) and VOHHS(DN)) of the

DUT Data & Clock Lanes HS transmitter are less than the maximum conformance limit.

VOHHS-Dn

VOHHS-CLKp

VOHHS-CLKn

BRIEF HS RISE & FALL TEST DESCRIPTIONS

Name

Purpose

TR-DATA

To verify that the 20%-80% Rise Time (tR) of the DUT Data & Clock Lanes HS transmitter is within

the conformance limits.

TR-CLK

TF-DATA

To verify that the 80%-20% Fall Time (tF) of the DUT Data & Clock Lanes HS transmitter is within

the conformance limits.

TF-CLK

LP (Low Power) Tests

BRIEF LP LEVELS TEST DESCRIPTIONS

Name

Purpose

VOH-Dp

To verify that the Thevenin Output High Level Voltage (VOH) of the DUT’s Data & Clock Lanes

LP transmitter is within the conformance limits.

VOH-Dn

VOH-CLKp

VOH-CLKn

VOL-Dp

To verify that the Thevenin Output Low Level Voltage (VOL) of the DUT’s Data & Clock Lanes

LP transmitter is within the conformance limits.

VOL-Dn

VOL-CLKp

VOL-CLKn