beautypg.com

5 link command packet members, 6 skip packet members, 7 logical idle packet members – Teledyne LeCroy Verification Script Engine (VSE) Manual User Manual

Page 25: 8 link management packet members, 9 isochronous timestamp packet members

background image

Teledyne LeCroy

Verification Script Engine Reference Manual




Page 25 of 115



5.2.1.3.5

Link Command Packet Members

in.LnkCmd:

Index of the Link Command type (constants are defined in VS_constants.inc)

in.LinkCmdInfo:

Value of the Link Command Information field for the Link Command Word

in.CRC5:

Value of CRC5 for the Link Command Word

in.LinkCmdInfo_2:

Value of the Link Command Information field for the replica of the Link Command Word

in.CRC5_2:

Value of CRC5 for the replica of the Link Command Word

5.2.1.3.6

SKIP Packet Members

in.Count:

Count of symbols in the SKIP sequence

5.2.1.3.7

Logical Idle Packet Members

in.Count:

Count of symbols in the Logical Idle sequence

5.2.1.3.8

Link Management Packet Members

in.SubType:

SubType value for LMP. Use constant definitions in VS_constants.inc.

5.2.1.3.9

Isochronous Timestamp Packet Members

in.BusICounter:

Bus Interval Counter value for ITP, in 1/8 of a millisecond

in.Delta:

Time Delta value for ITP

in.BusIAdjCtrl:

Bus Interval Adjustment Control value for ITP, specifying the device in control of

bus interval adjustment