Specifications – LEESON Chassis Mount Regenerative Control: 175721.00 User Manual
Page 7
1
Specifications
Max.
Armature
HP Range
HP Range
Current
with 115 VAC
with 230 VAC
Model
(Amps DC)
Applied
Applied
175720.00
10.0 †
1/4 – 1 †
1/2 – 2 †
175721.00
10.0 †
1/4 – 1 †
1/2 – 2 †
† Maximum armature current and horsepower range apply when drive is attached to
additional heat sink part number 175722. Use heat sink when armature current is
above 7 ADC. Heat sinks are pre-mounted on cased drives.
AC Line Voltage
115/230 VAC, ±10%, 50/60 Hz, single phase
Armature Voltage (115 VAC Input)
0 – 90 VDC
Armature Voltage (230 VAC Input)
0 – 180 VDC
Form Factor
1.37 at base speed
Field Voltage (115 VAC Input)
50 VDC (F1 to L1); 100 VDC (F1 to F2)
Field Voltage (230 VAC Input)
100 VDC (F1 to L1); 200 VDC (F1 to F2)
Max. Field Current
1 ADC
Accel. Time Range (with no load)
0.5 –10 seconds
Decel. Time Range (with no load)
0.5 –10 seconds
Analog Input Voltage Range (isolated; RB1 to S2)
0 –10 VDC
Input Impedance (S0 to S2)
32K ohms
Load Regulation
with Armature Feedback
1% of base speed or better
with Tachogenerator Feedback
0.1% of base speed
Ambient Temp. Range (chassis drive)
10°C – 55°C
Ambient Temp. Range (cased drive)
10°C – 40°C