Check selector switch settings
1. Set both line voltage selector switches (SW501 and SW502)
to 115 if using 115 VAC line voltage, or to 230 if using 230
VAC line voltage.
2. Set the armature voltage selector switch (SW503) to 90 if
using a 90 VDC motor, or to 180 if using a 180 VDC motor.
3. Set the feedback selector switch (SW504) to TACH if using
a tachogenerator; otherwise, set it to ARM for armature
feedback.
Note: You may be required to derate a 90 VDC motor when
230 VAC is applied to the drive. Contact Leeson for details.
See Figure 12 on page 19 for switch locations.
18
Before applying power
1. Check connections before applying AC line voltage to the drive.
2. Check that no conductive material is present on the printed
circuit board.
3. Verify that all selector switches are set correctly (see the
following section for selector switch settings).
Operation