Startup, Chassis drives – LEESON Chassis Mount Regenerative Control: 175721.00 User Manual
Page 26

20
Operation
Startup
Chassis drives
Uni-directional Operation
1. Set the speed adjust potentiometer to minimum (full
CCW).
2. Apply AC line voltage.
3. Slowly turn the speed adjust potentiometer clockwise
(CW). The motor will accelerate as the potentiometer is
turned CW. Continue until the desired speed is
reached.
4. Remove AC line voltage from the drive to coast the
motor to a stop.
Bi-directional Operation
1. Set the speed adjust potentionmeter to minimum
(center position).
2. Apply AC line voltage.
3. Slowly turn the speed adjust potentiometer either
clockwise for forward direction, or counterclockwise for
reverse direction. The motor will accelerate as the
potentiometer is turned. Continue until the desired
speed is reached.
4. Remove AC line voltage from the drive to coast the
motor to a stop.