LEESON Micro Series Compact Inverters User Manual
Page 49

47
17.0 PARAMETER MENU
NOTE 1: REFER TO SECTION 18 .0 - DESCRIPTION OF PARAMETERS .
NOTE 2: MAX LIMIT IS 650 Hz ON UNITS WITH HIGH FREQUENCY SOFTWARE.
NOTE 3: IF LINE VOLTS IS SET TO “LOW” (OR SET TO “AUTO” AND THE INPUT
VOLTAGE IS LOW), RANGE IS 25 - 150%.
PARAMETER MENU
PARAM.
PARAMETER
RANGE OF
FACTORY
NUMBER
NAME
ADJUSTMENT
DEFAULT
0
LINE VOLTS
HIGH, LOW, AUTO
AUTO
1
SPEED #1
MIN FRQ - MAX FRQ
20.00 Hz
2
SPEED #2
MIN FRQ - MAX FRQ
20.00 Hz
3
SPEED #3
MIN FRQ - MAX FRQ
20.00 Hz
4
SPEED #4
MIN FRQ - MAX FRQ
20.00 Hz
5
SKIP #1
.00 Hz - MAX FRQ
0.00 Hz
6
SKIP #2
.00 Hz - MAX FRQ
0.00 Hz
7
BAND WID
.00 - 10.00 Hz
1.00 Hz
8
ACCEL
NOTE 1
30 .0 SEC
9
DECEL
NOTE 1
30 .0 SEC
10
MIN FRQ
.00 - MAX FRQ
0.50 Hz
11
MAX FRQ
MIN FRQ - 120.0 HZ (NOTE 2)
60.00 Hz
12
DC BRAKE
NOTE 1
0 .0 VDC
13
DC TIME
.0 - 999 .9 SEC
0 .0 SEC
14
DYN BRAKE
OFF, ON
OFF
16
CURRENT
25 - 180% (NOTE 3)
180%
17
MOTOR OL
25 - 100%
100%
18
BASE
20.00 - 360.0 Hz (NOTE 2)
60.00 Hz
19
FX BOOST
.0 - 30 .0%
NOTE 1
20
AC BOOST
.0 - 20 .0%
0 .0%
21
SLIP COMP
.0 - 5 .0%
0 .0%