KB Electronics KBRG-212D User Manual
Page 22
22
7.5 J8 – Analog (Signal) Input Voltage –
The output of this control is normally controlled
with the main potentiometer. However, an
analog voltage (isolated) may also be used in
place of a potentiometer. The control can be
scaled for 0 – 10VDC by placing J8 in the
appropriate position "15V" or "10V". The scaling
can be further adjusted with the SCALE Trimpot.
Refer to Section 6.9, (Signal Following) on page
17, and Figure 16, for additional information.
7.6 J17 – Analog Signal Input – J17 is used in
conjunction with jumper J8 and the Main
Speed Potentiometer for, the input of a voltage
or a voltage or current signal
. Refer to Section
6.9, (Signal Following) on page 17 and Figures
17A and 17B.
7.7 J9 – Enable (EN) / Inhibit (INH) – The control
can be electronically stopped or started with the
inhibit circuit, depending upon the position of
Jumper, J9. The control can also be started and
stopped with the Enable (Factory Set) function.
(The enable circuit functions opposite to that of
the inhibit circuit). See Figure 18 and Section
6.10, on page 18, for wiring information.
FIGURE 16 - J8 15V / 10V
JUMPER
J8
10V
15V
15V
J8
10V
(Shown in the 10V Position)
(Shown in the 15V Position)
Default Position
FIGURE 17A - J17
ANALOG SIGNAL INPUT
“VOLTAGE POSITION (DEFAULT)”
FIGURE 17B - J17
ANALOG SIGNAL INPUT
“CURRENT POSITION”
VOLT CUR
J17
VOLT CUR
J17
FIGURE 18 - J9 ENABLE /
INHIBIT JUMPER
J9
EN
INH
J9
INH
EN
(Shown in the Enable Position)
(Shown in the Inhibit Position)