KB Electronics KBAC-29 (1P) User Manual
Page 23
22
12 TRIMPOT ADJUSTMENTS
The drive contains trimpots which are factory set for most applications.
See Figure 2, on page 9, for the location of the trimpots and their
approximate factory calibrated positions. Some applications may require
readjustment of the trimpots in order to tailor the drive for a specific
requirement. The trimpots may be readjusted as described below.
WARNING! If possible, do not adjust trimpots with the
main power applied. If adjustments are made with the
main power applied, an insulated adjustment tool must be used and
safety glasses must be worn. High voltage exists in this drive. Fire
and/or electrocution can result if caution is not exercised. Safety
Warning, on page 5, must be read and understood before
proceeding.
12.1 MINIMUM SPEED (MIN) – Sets the minimum speed of the
motor. The MIN Trimpot is factory set to 0% of frequency setting.
For a higher minimum speed setting, rotate the MIN Trimpot
clockwise. See Figure 30.
12.2 MAXIMUM SPEED (MAX) – Sets the maximum speed of the
motor. The MAX Trimpot is factory set to 100% of frequency set-
ting. For a lower maximum speed setting, rotate the MAX Trimpot
counterclockwise. For a higher maximum speed setting, rotate
the MAX Trimpot clockwise. See Figure 31.
12.3 ACCELERATION (ACCEL) – Sets the amount of time for the
motor to accelerate from zero speed to full speed. The ACCEL
Trimpot is factory set to 1.5 seconds. For a longer acceleration
time, rotate the ACCEL Trimpot clockwise. For more rapid
acceleration, rotate the ACCEL Trimpot counterclockwise.
See Figure 32.
Note: Rapid acceleration settings may cause the current limit circuit to activate, which will extend the
acceleration time.
the user that all drive and microcontroller operating parameters are normal. Table 7, summarizes the
“ST” LED functions.
Drive Operating Condition
Flash Rate
1
and LED Color
Normal Operation
Slow Flash Green
Overload (120% – 160% Full Load)
Steady Red
2
I
2
t (Drive Timed Out)
Quick Flash Red
2
Short Circuit
Slow Flash Red
Undervoltage
Quick Flash Red / Yellow
3
Overvoltage
Slow Flash Red / Yellow
3
Stop
Steady Yellow
Stand-By
4
Slow Flash Yellow
TABLE 7 – DRIVE OPERATING CONDITION AND STATUS LED INDICATOR
Notes: 1. Slow Flash = 1 second on and 1 second off. Quick Flash = 0.25 second on and 0.25 second off. 2. When the Overload is
removed, before the I
2
t times out and trips the drive, the “ST” LED will flash green. 3. When the Undervoltage or Overvoltage condition is
corrected, the “ST” LED will flash Red / Yellow / Green. 4. Only if the Forward-Stop-Reverse Switch is installed.
(Shown Factory Set to 0% Frequency Setting)
0
MIN
40
15
35
30
FIGURE 30 – MINIMUM SPEED
TRIMPOT RANGE
(Shown Factory Set to 100% Frequency Setting)
70
MAX
110
75
90
100
80
FIGURE 31 – MAXIMUM SPEED
TRIMPOT RANGE
0.3
(Shown Factory Set to 1.5 Seconds)
ACCEL
20
3
1.5
17
10
FIGURE 32 – ACCELERATION
TRIMPOT RANGE