beautypg.com

American Dryer Corp. Phase 5 Microprocessor AD-170 User Manual

Page 22

background image

18

To Test and Adjust Gas (Water Column) Pressure

There are two (2) types of devices commonly used to measure water column pressure. They are spring/mechanical-

type gauges and manometers. The spring/mechanical-type gauge is not recommended, because it is easily

damaged and not always accurate. A manometer is simply a glass or transparent plastic tube with a scale in

inches. When filled with water and pressure applied, the water in the tube rises showing the exact water column

pressure.

NOTE: Manometers are available from the factory by ordering ADC P/N 122804

1. To Test Gas Water Column (W.C.) Pressure:

a. Connect water column test gauge connection

to gas valve pressure tap (1/8" NPT). This

pressure tap is located on the outlet (manifold)

side of the valve.

b. Start dryer. With burner on, the correct water

column reading in inches would be:

Natural Gas – 3.5 to 4 Inches Water Column

L.P. Gas – 10.5 to 11 Inches Water Column

2. To Adjust Water Column Pressure (natural gas only,

L.P. gas must be regulated at source):

a. Remove the slotted vent cap on the top of the valve.

b. Turn the slotted adjustment screw located on the top

of the valve next to the terminals. Turn clockwise to

increase manifold pressure and counterclockwise to

decrease.

NOTE: If correct W.C. pressure cannot be achieved, problem may be due to an undersized gas

supply line, a faulty or underrated gas meter, etc.