Table 7-1 Troubleshooting Guide

Symptom

Cause

Remedy

Hoist operates
intermittently

Collectors making poor
contact

Check movement of spring loaded arm, weak spring, connections,
and shoe. Replace as needed.

Contactor contacts
arcing

Check for burned contacts. Replace as needed.

Loose connection in
circuit

Check all wires and terminals for bad connections. Replace as
needed.

Broken conductor in
Pendant Cord

Check for intermittent continuity in each conductor the Pendant
Cord. Replace entire Pendant Cord if continuity is not constant.

DA Model - Hook
drops out of cylinder
chuck

Worn or deformed Ball
Guide Tube

Check Ball Guide Tube for excessive wear or deformation.
Replace as needed.

Actuation of Limit
Switch does not stop
hoist

Limit switch defective

Repair or replace as required.

Bent or worn lever;
Lever should move
freely.

Repair or replace as required.