Changing fahrenheit (f) to celsius (c), Quickset™ programming mode – Robertshaw 9610 User Manual
Page 6

3. Press
Press
To change
Temperature Differential*
*T
HE
T
EMPERATURE
D
IFFERENTIAL IS
F
ACTORY PRESET AT
1°. T
HIS MEANS
THAT WHENEVER THE ROOM TEMPERATURE CHANGES BY ONE FULL DEGREE FROM
THE TEMPERATURE SETTING
,
THE SYSTEM WILL TURN ON
. I
F THE SYSTEM TURNS
ON TOO OFTEN
,
INCREASE THE TEMPERATURE DIFFERENTIAL
.
4. Press
Press
To change
Residual Cooling**
**T
HE RESIDUAL COOL FEATURE WILL KEEP THE SYSTEM FAN ON FOR AN ADDITIONAL
30, 60
OR
90
SECONDS AFTER THE COMPRESSOR CYCLES OFF
. R
ESIDUAL
C
OOLING CAN ONLY BE PROGRAMMED WHEN
SETTING THE COOLING PROGRAM
.
Changing Fahrenheit (F) to Celsius (C)
Press and Hold SET
Press
Release both simultaneously.
QuickSet™ Programming Mode*
1. Place COOL-OFF-HEAT
in HEAT or COOL position.
2. Press & Hold SET. Press the
d button.
Release simultaneously.
3. The MORN indicator should be blinking. Program the Time-of-Day and
the temperature as outlined in the Setting Daily Program section.
*QuickSet™ will program all 7 days of the week with the same program.
Individual days can then be changed or modified.