SAFETY GROUND

Install the ground wire assembly supplied with the

Evolver MicroPak Controller from the ground stud

on the rear of the controller to a true earth ground.

For maximum noise immunity, cut the ground

wire assembly to the shortest length required and

reinstall the end lug before making connections.

LOW VOLTAGE CABLE

Standard Low Voltage Cable

(A11353-XX)

Plug the connector of the low voltage cable assem-

bly into the appropriate receptacle on the rear of

the controller (see Figure 3). P1 is the output for

the leftmost MicroPak control unit, when viewed

from the front, and P2 is the output for the rightmost

MicroPak control unit, if installed. When making

the connection, line the red dot on the connector

with the red mark on the receptacle and push

in until it clicks. To remove, simply pull back on

the knurled portion of the connector. Attach the

low voltage cable(s) to the stress relief bar using

TR-SSEM-200 cable ties (supplied) as shown in

Figure 3.

Junction Box Cables

(A11355-XX and A11356-XX)

The Evolver spray gun can be ordered with special

low voltage cables (A11355-XX and A11356-XX)

for splicing to a junction box. This is sometimes

done in the field, to reduce the amount of cable that

has to be replaced if a failure of the cable occurs.

The control unit and gun ends of these cables

attach as described in the standard low voltage

cable section above. Follow the instructions below

to wire the junction box ends of these cables:

Junction Box in Hazardous Location

If the junction box is in the hazardous location,

an explosion-proof junction box must be used. In

this case, connect the numbered wires of cable

A11356-XX to the same numbered wire of cable

A11355-XX using a terminal strip inside the ex-

plosion-proof junction box. Ensure the junction

box is grounded to earth ground. Connect wire

18 (braid) of cable A11355-XX to the junction box

(ground). Seal the cable in the explosion-proof

junction box using appropriate explosion-proof

fittings and sealing compound. The exposed area

of the cable braids must be located on the junction

box side of the sealing compound.

Junction Box in Non-Hazardous

Location

If the junction box is in a non-hazardous location,

then it is not necessary to use an explosion-proof

junction box. In this case, use the supplied cable

gland (A11357-02) and gland nut (A11358-02)

to secure the cables at their entry and exit to the

junction box. Install the cable gland in the junction

box and position the cable so that the spring of the

gland makes contact to the exposed braid of the

cable when the gland nut is tightened. Ensure the

junction box is grounded to earth ground. Connect

the numbered wires of cable A11356-XX to the

same numbered wire of cable A11355-XX using

a terminal strip inside the junction box. The braid

of cable A11355-XX will be grounded through its

contact to the cable gland spring and the grounded

junction box. Wire 18, therefore is unnecessary

and may be trimmed off. Connection in this manner

will ensure maximum noise immunity.

†

The ground wire assembly MUST be con-

nected from the Evolver MicroPak Controller

ground stud to a true earth ground.