Figure 1: Terminal Block 1 (1TB

W A R N I N G

!

Always double check that the control unit is

unplugged from its AC outlet before working

with any internal wiring.

INSTALLATION

MICROPAK INPUT

POWER

For non-conduit installations, plug the detachable

AC line cord into the receptacle on the rear of the

Evolver MicroPak Controller. Plug the other end

of the line cord into a properly grounded 120 Volt

AC outlet.

In general, conduit must be used for ap-

proved AC installation, however, if national

and local codes permit, the AC power may

be supplied via the factory supplied line

cord.

NOTE

Figure 2: Installation of Conduit Adapter Plate

For installations where it is required to run the AC

input wiring in conduit, perform the following:

1. Ensure the AC line cord is unplugged and remove

the top cover from the controller (see Figure 9).

2. Remove the AC Inlet Receptacle wiring from

1TB-L1, 1TB-N, and 1TB-Ground (see Figure 1

for AC input wiring locations).

3. Remove the mounting hardware from the AC

Inlet Receptacle and remove it from the rear of

the control unit.

4. Install the Conduit Adapter Plate (supplied)

in the hole where the AC Inlet Receptacle was

removed (see Figure 2).

5. Install the AC line cord through the Conduit

Adapter Plate using conduit and wire to 1TB as

follows:

Hot/Line

to

1TB-L1

Neutral/common

to

1TB-N

Ground

to

1TB-Ground

6. Reinstall top cover on controller.

Evolver MicroPak Controller - Installation

Ransburg

10

LN-9622-00.5