Installation, Ransburg, Micropak input power – Ransburg Evolver MicroPak Controller A10406 User Manual
Page 13
Figure 1: Terminal Block 1 (1TB
W A R N I N G
!
Always double check that the control unit is
unplugged from its AC outlet before working
with any internal wiring.
INSTALLATION
MICROPAK INPUT
POWER
For non-conduit installations, plug the detachable
AC line cord into the receptacle on the rear of the
Evolver MicroPak Controller. Plug the other end
of the line cord into a properly grounded 120 Volt
AC outlet.
In general, conduit must be used for ap-
proved AC installation, however, if national
and local codes permit, the AC power may
be supplied via the factory supplied line
cord.
NOTE
Figure 2: Installation of Conduit Adapter Plate
For installations where it is required to run the AC
input wiring in conduit, perform the following:
1. Ensure the AC line cord is unplugged and remove
the top cover from the controller (see Figure 9).
2. Remove the AC Inlet Receptacle wiring from
1TB-L1, 1TB-N, and 1TB-Ground (see Figure 1
for AC input wiring locations).
3. Remove the mounting hardware from the AC
Inlet Receptacle and remove it from the rear of
the control unit.
4. Install the Conduit Adapter Plate (supplied)
in the hole where the AC Inlet Receptacle was
removed (see Figure 2).
5. Install the AC line cord through the Conduit
Adapter Plate using conduit and wire to 1TB as
follows:
Hot/Line
to
1TB-L1
Neutral/common
to
1TB-N
Ground
to
1TB-Ground
6. Reinstall top cover on controller.
Evolver MicroPak Controller - Installation
Ransburg
10
LN-9622-00.5