INTRODUCTION
SPECIFICATIONS
(At Sea-Level Conditions)
Environmental / Physical
Electrical
DC Power Required: *
(per MicroPak)
24 VDC at 2.5A
(fully loaded output),
HP404, Cascade
AC Electrical Requirements:
90-264 VAC @ 1.5 amps @
47/63 Hertz
Temp. Operating:
(0
o
to 55
o
C)
Storage:
(-40
o
C to 85
o
C)
Humidity:
(95% Non-Condensing)
Cabinet Size:
13.0” Wide
19.0” Deep
7.0” Height
Weight:
19 lbs.
* DC power supplied from 24VDC built-in, regu-
lated power supy which has overcurrent (40%)
and overvoltage (20%) protection.
GENERAL DESCRIPTION
The Evolver MicroPak
TM
Controller, is used to
provide voltage to the cascade inside the Evolver
Spray Gun Assembly.
The Evolver MicroPak Controller together with the
Evolver Spray Gun Assembly and it’s Low Voltage
Cable is an “FM” Listed System. It is unique in
that it contains a built-in DC Power Supply and is
capable of operating either 1 or 2 Evolver Micro-
Pak control units.
The MicroPak uses a combination of proven high
voltage generation technology including micropro-
cessor-based control with diagnostic and commu-
nication functions. The processor circuitry provides
the maximum in applicator transfer efficiency, while
maintaining the maximum safety when used in
conjunction with FM listed applicators.
SAFETY FEATURES
When used with FM listed applicators, the Mi-
croPak provides the ultimate in operational safety.
The microprocessor circuits allow the use of output
load curve control, which limits the high voltage
output to safe levels, even with the controls set
at maximum levels, and does so without a hard
shut down. The Over-current setpoint, which can
be monitored on the μa Display by pressing the
SET push-button and holding for one second,
does provide a hard shut down if the output
current exceeds the setpoint. The KV setpoint is
also displayed on the KV display when the SET
pushbutton is pressed for one second.
DISPLAYS
The front panel displays for output voltage and
current indicate the true outputs from the cas-
cade or the tip voltage for indirect charge, and
waterborne applications. They are derived from
feedback signals in the low voltage cable between
the controller and the cascade.
Evolver MicroPak Controller - Introduction
Ransburg
8
LN-9622-00.5