INTRODUCTION

SPECIFICATIONS

(At Sea-Level Conditions)

Environmental / Physical

Electrical

DC Power Required: *

(per MicroPak)

24 VDC at 2.5A

(fully loaded output),

HP404, Cascade

AC Electrical Requirements:

90-264 VAC @ 1.5 amps @

47/63 Hertz

Temp. Operating:

(0

o

to 55

o

C)

Storage:

(-40

o

C to 85

o

C)

Humidity:

(95% Non-Condensing)

Cabinet Size:

13.0” Wide

19.0” Deep

7.0” Height

Weight:

19 lbs.

* DC power supplied from 24VDC built-in, regu-

lated power supy which has overcurrent (40%)

and overvoltage (20%) protection.

GENERAL DESCRIPTION

The Evolver MicroPak

TM

Controller, is used to

provide voltage to the cascade inside the Evolver

Spray Gun Assembly.

The Evolver MicroPak Controller together with the

Evolver Spray Gun Assembly and it’s Low Voltage

Cable is an “FM” Listed System. It is unique in

that it contains a built-in DC Power Supply and is

capable of operating either 1 or 2 Evolver Micro-

Pak control units.

The MicroPak uses a combination of proven high

voltage generation technology including micropro-

cessor-based control with diagnostic and commu-

nication functions. The processor circuitry provides

the maximum in applicator transfer efficiency, while

maintaining the maximum safety when used in

conjunction with FM listed applicators.

SAFETY FEATURES

When used with FM listed applicators, the Mi-

croPak provides the ultimate in operational safety.

The microprocessor circuits allow the use of output

load curve control, which limits the high voltage

output to safe levels, even with the controls set

at maximum levels, and does so without a hard

shut down. The Over-current setpoint, which can

be monitored on the μa Display by pressing the

SET push-button and holding for one second,

does provide a hard shut down if the output

current exceeds the setpoint. The KV setpoint is

also displayed on the KV display when the SET

pushbutton is pressed for one second.

DISPLAYS

The front panel displays for output voltage and

current indicate the true outputs from the cas-

cade or the tip voltage for indirect charge, and

waterborne applications. They are derived from

feedback signals in the low voltage cable between

the controller and the cascade.